User manual AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE. We hope that this AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE user guide will be useful to you.


AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE : Download the complete user guide (509 Ko)

Manual abstract: user guide AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE

Detailed instructions for use are in the User's Guide.

[. . . ] Please Read Before Installing Installation Instructions Overview The 4 Series Low-voltage Rough-in Enclosure provides a compact housing for mounting the 4 Series processor. The enclosure accepts one 120 V feed to power the processor and its connected keypads. The enclosure's main feed is self-contained in an enclosed high-voltage area, eliminating exposure of high voltage connections when the enclosure cover is removed for low-voltage wiring. [. . . ] Surface Mount - Use keyholes shown in Mounting Diagram (page 1)with bolts sufficient for 30 lbs. (14 kg) through the sides of the enclosure (see Mounting Diagram, page 1). Danger - Locate and lock supply breaker in the OFF position before connecting power input. Wiring Diagram Low-voltage wiring entry Additional Low-voltage wiring entry No high-voltage in shaded area (Class 2 only) 2. Locations to run power wiring into the enclosure are as shown in Wiring Diagram. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. Strip insulation 1/2 in. Use to join one or two 12 or 14 AWG supply wires with one 10, 12, 14, 16 or 18 AWG control wire. Power wiring entry (remove high-voltage cover to access) High-voltage section Connect Hot/Live feed to the black wire, Neutral feed to the white wire, and Earth Ground to the green wire. If the processor and the accessory boards are not to be installed at this time, install the enclosure cover. (Instructions for installing the processor and accessory boards are supplied with the processor). (2. 3 Nm). LIMITED WARRANTY Technical and Sales Assistance If you need assistance, call the toll-free Lutron Technical Support Center. (800) 523-9466 (U. S. A. , Canada and the Caribbean) Other countries call: Tel: (610) 282-3800 Fax: (610) 282-3090 Visit our Web site at www. lutron. com Lutron Electronics Co. , Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U. S. A. A 93-2605-04 Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within two years after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd. , Coopersburg, PA 18036-1299, postage pre-paid. [. . . ] Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Lutron and HomeWorks are registered trademarks and 4 Series is a trademark of Lutron Electronics Co. , Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.