User manual AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER. We hope that this AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER user guide will be useful to you.


AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER : Download the complete user guide (332 Ko)

Manual abstract: user guide AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER

Detailed instructions for use are in the User's Guide.

[. . . ] This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. [. . . ] RS-232 Program connector RS-232 Program DIP switch TX1 and RX1 LEDs This DB-9 RS-232 connector is used for AMX programming tools, such as Axcess and IRLIB. The 8-position DIP switch configures the communication parameters for the Program port. The red LEDs indicate that the AXB-EM232 is receiving (RX) or transmitting (TX) RS-232, RS-422, or RS-485 data. RX1 and TX1 correspond to Port 1 on the rear panel (See Rear Panel Components for a description of Port 1). The two 8-position DIP switches configure the communication parameters for the Ports 1 and 2 (See Rear Panel Components for a description of Ports 1 and 2). The red LEDs indicate that the AXB-EM232 is receiving (RX) or transmitting (TX) RS-232 data. RX2 and TX2 correspond to Port 2 (See Rear Panel Components for a description of Port 2). 64 KB battery protected memory, expandable to 256 KB Asynchronous data communication · Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 RS-232/422 1 and 2 DIP Switches TX2 and RX2 LEDs Rear Panel Components: Ports 1 and 2 AXlink connector Power supply connector Enclosure Dimensions (HWD) Weight Mounting options Optional Accessories: Power Supply Mounting Hardware · PSN2. 8 (FG423-05) · PSN6. 5 Domestic (FG423-41), International (FG423-43) AC-RK Accessory Rack Kit (FG515) There are two serial connectors: Port 2 is a 6-wire RS-232 captive-wire connector; Port 1 is an 8-wire RS-232/422 captive wire connector. The AXlink connector is a 4-wire, captive-wire connector for data and power. The PWR connector is a 2-wire, captive-wire connector for the 12 VDC power supply. Non-glare, high-impact black plastic 1. 5" x 5. 6" x 6. 5" (3. 8 cm x 14. 1 cm x 16. 4 cm) 1. 1 lbs (501. 7 g) Rack mounting with the optional AC-RK Accessory Rack Kit 2 AXB-EM232 Enhanced Master RS-232 Controller Product Information Installation Setting the internal jumpers Some RS-232 devices require that the bus be terminated at 100 ohms. Remove the front panel, and slide the circuit board out of the enclosure. Remove the jumper on pin trio E1 from pins 2-3 and place it on pins 1-2 (FIG. Then, replace the front panel, refasten the two screws, and plug in the two-wire power connector. Setting DIP switches Configure the device and programming communication ports' baud rate, data bits, stop bits, and parity. Use the eight-position DIP switches on the front panel to set the communications parameters. ! RS-232 PROGRAM DIP switch - Use the eight-position RS-232 Program DIP switch to set the communications parameters for the PROGRAM port. RS-232/422 DIP switches - Use the two eight-position RS232/422 DIP switches to set communications parameters for controlling the RS-232, RS-422, or RS-485 devices. ! ! ·Set Switch 1 to configure the parameters for Port 1 (RS-232/422/485). Set Switch 2 to configure the parameters for Port 2 (RS-232 only). ! AXB-EM232 Enhanced Master RS-232 Controller 3 Product Information Refer to the following table when setting the DIP switches. Communication Parameters DIP Switch Settings Switch 1 2 3 4 Parity Off Off Unused On Off Unused Off On Unused On On Unused Off Off Mark On Off Even Off On Odd On On None On On On Off On On On Off Off On Off Off Off On Off Off 5 6 7 Baud Rates Off 300 Off 600 On 1, 200 On 2, 400 Off 4, 800 Off 9, 600 On 19, 200 On 38, 400 On On On On Off Off Off Off 8 Function Stop Bits Data Bits Setting Value Off 2 bits On 1 bit Off 7 bits On 8 bits Wiring Devices to the AXB-EM232 The AXB-EM232 has captive-wire connectors on the rear panel (FIG. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section. Do not tighten the screws excessively; doing so may strip the threads and damage the connector. Using AXlink Connect the AXlink wiring to the connector on the AXB-EM232, as shown in FIG. [. . . ] Send_String sequences "27, 17, <time in 100 microsecond increments 1-255>" Sends a break character of the specified length of time. "27, 18, 1" Sets the 9 data bit to 1 for all subsequent characters to be transmitted. Clears the 9 data bit to 0 for all subsequent characters to be transmitted. Asserts RTS hardware handshake output low (Device 2). "27, 18, 0" "27, 19, <time in 1 millisecond increments 1-255>" "27, 20, 0" "27, 20, 1" Xmodem timing commands The following table lists the AXB-EM232 Xmodem timing commands. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXB-EM232 ENHANCED MASTER RS-232 CONTROLLER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.