User manual AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS. We hope that this AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS user guide will be useful to you.


AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS : Download the complete user guide (388 Ko)

Manual abstract: user guide AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual AXB-IRS4 IR/Serial Interface (4 Ports) AXlink Bus Controllers AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are warranted for a period of one (1) year. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. Batteries and incandescent lamps are not covered under the warranty. This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. [. . . ] RS232 communication To set internal jumpers E1 and E2 for RS-232 communication (FIG. Replace the front or rear panel, refasten the two Phillips-head screws, and plug in all connectors. AXB-IRS4 IR/Serial Interface (4 Ports) 5 Configuration and Installation Wiring the AXB-IRS4 The serial, IR, AXlink, and power supply connectors are located on the rear panel of the AXB-IRS4 as shown in FIG. The AXlink connector can also be used for RS-232 communications. AXM / RX AXP / TX GND GND GND GND GND GND GND 4 3 GND SER SER SER IR IR IR SER IR 2 1 AXlink / RS-232 PWR GND 12VDC PWR FIG. 5 AXB-IRS4 rear panel connectors Do not connect power to the AXB-IRS4 until the wiring is complete. If you are using power from AXlink, disconnect the wiring from the Card-Frame before wiring the AXB-IRS4. If you are using an optional 12 VDC power supply, apply power to the AXB-IRS4 only when the installation is complete. Wiring Guidelines The AXB-IRS4 requires 12 VDC power to operate properly. The power can be supplied by the AMX system's AXlink cable or with an optional 12 VDC power supply. The maximum wiring distance between the control system and AXB-IRS4 is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The following table lists wire sizes and the maximum lengths allowable between the AXB-IRS4 and control system. The maximum wiring lengths for using AXlink power are based on a minimum of 13. 5 volts available at the control system's power supply. Wiring Guidelines at 125 mA Wire Size 18 AWG 20 AWG 22 AWG 24 AWG Maximum Wiring Length 938. 97 feet (286. 19 m) 594. 06 feet (181. 07 m) 370. 37 feet (112. 89 m) 233. 46 feet (71. 16 m) If the AXB-IRS4 is installed farther away from the control system than recommended in the Wiring Guidelines table, connect a 12 VDC power supply to the 2-pin 12 VDC PWR connector on the rear panel. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section. Do not tighten the screws excessively; doing so may strip the threads and damage the connector. 6 AXB-IRS4 IR/Serial Interface (4 Ports) Configuration and Installation Using AXlink for data and power Connect the Central Controller's AXlink connector to the AXlink/RS-232 connector, on the rear panel of the AXB-IRS4, for data and 12 VDC power, as shown in FIG. 6. 12 VDC PWR connector on AXB-IRS4 PWR (+) GND (-) PWR(+) no connection PWR AXP AXM GND AXlink/RS232 connector on AXB-IRS4 AXP/TX AXM/RX GND (-) Axcess Control System FIG. 6 AXlink data and power wiring diagram Using AXlink for data and a 12 VDC power supply Connect the Central Controller's AXlink connector to the AXlink/RS-232 connector, on the rear panel of the AXB-IRS4, and the optional 12 VDC power supply, as shown in FIG. 7. 12 VDC PWR connector on AXB-IRS4 PWR (+) GND (-) PWR(+) 12 VDC power supply PWR AXP AXM GND AXlink/RS232 connector on AXB-IRS4 AXP/TX AXM/RX GND (-) Axcess Control System FIG. 7 AXlink and optional 12 VDC power supply wiring diagram Use the 12 VDC power supply when the distance between the AMX system and AXB-IRS4 exceeds the limits described in the Wiring Guidelines at 125 mA table on page 6. Make sure to connect only the GND wire on the AXlink/RS-232 connector when using a 12 VDC power supply. Do not connect the PWR wire to the AXlink connector's PWR opening. Using the AXlink-to-DB-9 connector cable for a PC system To use a PC, set the internal jumpers for RS-232 communication mode and the DEVICE DIP switch positions 1 - 8 off (down). The AXlink/RS-232 connector, on the back of the AXB-IRS4, can be connected to a PC system using a DB-9 connector cable. DB-9 Wiring Pinouts Pin Signal Function 1 2 3 4 5 N/A RXD TXD DTR GND Not used Receive data Transmit data Data terminal ready (not used) Signal ground Pin Signal Function 6 7 8 9 N/A RTS CTS N/A Not used Request to send (not used) Clear to send (not used) Not used AXB-IRS4 IR/Serial Interface (4 Ports) 7 Configuration and Installation FIG. For some applications, you may need to strap pins 7 (request to send) and 8 (clear to send) together depending on the PC (as shown in the illustration). 12 VDC PWR connector on AXB-CAM PWR (+) GND (-) 12 VDC power supply PWR(+) AXlink/RS232 connector on AXB-CAM AXP/TX AXM/RX GND (-) 2 (RXD) 3 (TXD) 5 (GND) DB-9 connector (male) FIG. [. . . ] Syntax: SEND_COMMAND <DEV>, 'XCH <Channel>' Variable: <Channel> = 0 through 999 RS-232 Protocol Commands The RS-232 protocol commands listed in the following tables send control signals from an RS-232 device to the AXB-IRS4. The following RS-232 figures are grouped together by IR output, channel pulse time, and carrier commands. RS-232 Protocol Commands (IR Output) RS-232 Protocol Commands (IR Output) Command CH[Dev, Chan] Description Transmit IR pulses to the designated device that selects the proper channel. If the IR code for ENTER (#21) is loaded, an ENTER follows the number. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXB-IRS4 IRSERIAL INTERFACE, 4 PORTS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.