User manual AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS). We hope that this AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS) user guide will be useful to you.


AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS) : Download the complete user guide (1080 Ko)

Manual abstract: user guide AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS)

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual Radia Lighting Control System Controllers, Modules, and Cards Lighting Controls AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] The pack number is determined by the value of all the switch position settings. The following table shows the SW2 DIP switch positions and their values. The lighting system will not work if you assign a pack number outside of the range. SW2 DIP Switch Setting Values for PROlink Position 1 2 3 4 5 6 7 8 Value 1 2 4 8 n/a n/a n/a All lights on 1. Locate the SW2 DIP switch on the controller circuit card (marked PROLINK ADDRESS), and set the pack number using the values shown in the proceeding table. The pack number must be 1 to 10. Assign pack 1 for all communications, diagnostics, and feedback response. 3. Connect the four-pin PROlink male connector to the four-pin female PROlink connector on the AMX Lighting controller. 14 Radia Lighting Control System Installation +12V PR+ PRGND PROlink wall panel +12V PR+ PRGND Radia PROlink connector FIG. 19 shows an example of how to interconnect two AMX Lighting RDD-DM4 controllers and a PROlink wall panel. Neutral Neutral HOT (1) HOT (2) RDD-DM4 (pack 1) RDD-DM4 (pack 2) PROlink connector (orange) PROlink PROlink connector (orange) PRO-DP8 wall panel FIG. 19 PROlink configuration sample Radia Lighting Control System 15 Installation Configuring and connecting AXlink On all AMX Lighting controllers, DIP switch SW1 sets the AXlink device number. The device number is determined by the value of all the switch position settings. The following table shows the SW1 DIP switch positions and their values. SW1 DIP switch setting values for AXlink Position 1 2 3 4 5 6 7 8 Value 1 2 4 8 16 32 64 128 1. Locate the SW1 DIP switch (AXLINK ADDRESS) on the controller circuit card and set the device number using the values shown in the proceeding table. Connect the four-pin AXlink male connector into the four-pin female AXlink connector on the controller circuit card. 20 shows how to wire the AXlink connector to a Central Controller system. (optional) +12V AXP/TX AXM/RX GND AXlink connector +12V AXP AXM GND Central Controller FIG. Connecting dry closures AMX Lighting controller modules contain eight connections for dry contact closures, and one common reference point. 21 shows the standard wiring configuration for the 9-pin dry closure connector. 16 Radia Lighting Control System Installation 1 2 3 4 5 6 7 8 C O M 9-pin Dry Closure Connector FIG. 21 9-pin dry closure connector (standard configuration) Each contact closure connection (1 through 8) is pre-programmed with a default preset. The following table shows the default presets for each contact closure. Dry closure default presets Contact closure Default function 1 2 3 4 5 6 7 8 Channel 1 at 100% in 1 second* Channel 2 at 100% in 1 second* Channel 3 at 100% in 1 second* Channel 4 at 100% in 1 second* Channel 5 at 100% in 1 second* Channel 6 at 100% in 1 second* Pack on (channels 1-6)* Pack off (channels 1-6)* *All other channels are undefined. Default Mode (Reset) Default mode is resetting the AMX Lighting module values to zero and the module then begins to function on the values you previously programmed into the module. If you experience problems after installing a lighting system, you may need to reset the controller module to default mode. Then, you should be able to determine if there is a problem with the connections, programming, and/or dimming. [. . . ] A preset can be dimmed so that all levels are zero and recovered or brought to full brightness and the dimmed back down to the original settings. PROlink - A four-wire data bus used to transmit and receive data from pack to pack. A PROlink address designates which six channels of control will be assigned to a pack, up to 10 pack addresses and 60 channels of control. Ramp - The increasing or decreasing of a light level on a continuous grade or increment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.