If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE. We hope that this AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE user guide will be useful to you.
Manual abstract: user guide AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Sheet
RDC-PDC Control Card, Dual or Three Phase (120 or 240 VAC)
The RDC-PDC Control Card module controls up to six dimmable channels with six satellite connectors (for RDM series dimmer or switching modules). The RDC-PDC is controlled by AXlink, PROlink, or by dry contact closures. [. . . ] 2 Connecting RDM series Note: The 4-pin plugs from the module connector to the 4-pin connector on the master (black plug cover facing up).
AXlink DIP switch PROlink DIP switch
Connecting AXlink
Control ports
Connect the 4-pin captive-wire AXlink connector from the RDC-PDC to the Central Controller for AXlink control of the dimming system.
PWR RDC-PDC AXP AXM GND (optional) PWR AXP AXM GND
FIG. 1 RDC-PDC control card
RDC-PDC UL and C-UL Ratings:
Control Input: · AXlink · PROlink · Eight dry closures Control Output: · Six control ports · Max. total control current at 300 mA Power Inputs: · Line 1 (channel 1 and 4) · Line 2 A (channel 5) · Line 2B (channel 2) · Line 3 (channel 3 and 6) · Neutral
Central Controller
FIG. 3 AXlink wiring
Connecting PROlink:
Connect the orange 4-pin captive-wire PROlink connector from the RDCPDC to a PRO-DP8 PROlink wall panel.
PRO-DP8 +12 PR+ PRGND FIG. 4 PROlink wiring Pack 1 Pack 2 +12 PR+ PRGND
Specifications:
· · · · · · · Dimensions (HW): 10. 0" x 2. 75" (254. 0 mm x 69. 85 mm) 12 VDC power (optional) Torque terminals to 20 in-lbs. wire size: 10 AWG Wire stripping length: 0. 28" (7 mm) Weight: 1. 5 lbs. (0. 68 kg) Power consumption: 50 mA @ 120 VAC 25 mA @ 240 VAC
Connecting Dry Closures
Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.
1 2 3 4 5 6 7 8 COM Each contact (1 - 8) is preprogrammed with a default preset. Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets. 5 Dry closures connection
Dry Closure Default Presets (Cont. )
5 6 7 8 Channel 5 at 100% in 1 second Channel 6 at 100% in 1 second Pack on (channels 1-6) Pack off (channels 1-6 All other channels are undefined.
Setting AXlink and PROlink Address Numbers:
AXlink Address PROlink Address Test
Each contact closure connection (1 - 8) is pre-programmed with a default preset. Dry Closure Default Presets
Contact Closure 1 2 3 4 Default Function Channel 1 at 100% in 1 second Channel 2 at 100% in 1 second Channel 3 at 100% in 1 second Channel 4 at 100% in 1 second
Set the AXlink address number (1-255) for the RDC-DC. This number must match the device number in your Axcess program.
Use the PROlink DIP switch to set the PROlink address number for the RDC-DC (1-10). Pin 8 on the PROlink DIP switch is a test switch that turns all circuits on to full.