User manual AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER. We hope that this AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER user guide will be useful to you.


AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER : Download the complete user guide (319 Ko)

Manual abstract: user guide AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER

Detailed instructions for use are in the User's Guide.

[. . . ] This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. [. . . ] All functions and capabilities of the UPC20+ (including information on high voltage wiring, low voltage wiring, and DIP switch settings) are described on a sticker installed inside the enclosure. 1 shows the UPC20+ (inside view). The UPC20+ will work the NXC-I/O10 input/output control card. UPC20+ Universal Power Controller 1 Product Information CAUTION GND SWITCH MUST MATCH INPUT VOLTAGE PRIOR TO APPLYING POWER TO UNIT RISK OF ELECTRIC SHOCK - MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED TO DE-ENERGIZE THE EQUIPMENT BEFORE SERVICING High voltage terminal and wiring arrangement label IMPORTANT 6 5 4 K2 3 2 K1 1 P1 TO CIRCUIT BD ELECTRONICS B L K 12 A W G B L K 1 2 AWG USE COPPER ONLY 75°C INSULATION High voltage wiring (120/240, 277 VAC) Power switch (115/230 VAC) Spade terminal block P1 Power and Motor control relays Test switches with status LEDs PB1 PB2 DIP switch controls mode and function ON 1234 Motor Time Delay Potentiometer Jumper JP1 JP1 REMOTE CONTACT LISTED IND. CONT. EQ. 68WF Low voltage and IR remote control connections P2 1 +12V PART # 91-0672-01, REV F 2 DATA 3 GND 4 GND 5 IN 1 67 IN 2 IN 3 8 IN 4 9 +12 C R US Low voltage terminal and wiring arrangement label UPC20+ Richardson, Texas 800-222-0193 469-624-8000 RECEIVER INPUT CLASS 2 CIRCUIT ONLY CONTROL INPUTS SEE INSIDE COVER FOR DETAILED WIRING AND DIP SWITCH INFORMATION NOTE: NO HIGH VOLTAGE THIS CONNECTION FIG. 1 UPC20+ The UPC+ cover contains information on high voltage wiring, low voltage wiring, and DIP switch settings. 2 UPC20+ Universal Power Controller Product Information Specifications UPC20+ Specifications Power Power input (for control board) Self-powered when used with 110/220 VAC 120/240V ~, 50-60 Hz, 0. 05/0. 025A -or12 VDC, 0. 2A max Power output per relay · 20A @ 120/240V ~, 50-60 Hz (RESISTIVE LOAD) · 6A @ 277V ~, 50-60 Hz (FLUORESCENT BALLAST) · 1 HP @ 120V ~, 50-60 Hz (INDUCTIVE LOAD) · 2 HP @ 240V ~, 50-60 Hz (INDUCTIVE LOAD) Total Current through both relays CAN NOT exceed 20 amp. Maximum operating ambient temperature Approvals Includes 55°C UL / C-UL / CE · 1-, 2-, and 3-button logic modes · Local test switches with status LEDs · 120, 240, and 277 VAC control capability Inputs · 4 closure inputs, operation defined by mode. · Motor Control mode alternates between the timed operation of the two power relays. · Power Control mode allows independent control of both power relays. · Set this switch according to the high voltage wiring that will be connected to terminals 5 and 6 on P1. · Set switch S1 to the line input voltage value used before applying power to the UPC20+. High Voltage Terminal Block (P1) High voltage input and output wiring for motor or power control. Low voltage and Control Terminal Block (P2) Jumper JP1 Test Switches (PB1 and PB2) Contact closure, open-collector or CMOS logic level remote control wiring. Sets control mode of the unit to contact closure or remote sensor serial data. Provides local operation of relays K1 and K2 for testing power circuits or motors connected to the relay terminals. User adjusted for setting relay release time between 0 and 90 seconds. See the Motor Control Mode DIP Switch S2 Positions table on page 5 and the Control Input Wiring to Connector P2 Terminals table on page 5 for control mode settings. · 8. 5" (10. 5" including flange) x 4. 5" x 2. 2" · (220 mm (270 including flange) x 110 mm x 60 mm) Weight Options 3. 0 lbs. (1. 4 kg) with flange 12 VDC power supply (for 277 VAC applications) Motor Time Delay Potentiometer (R8) DIP Switch (S2) Enclosure Dimension (HWD) UPC20+ Universal Power Controller 3 Product Information ATTENTION INSTALLER FACTORY SET TO INOPERATIVE MODE (UNIT WILL NOT WORK UNTIL DIP SWITCHES ARE SET) SEE CHART ON LID TO SET DIP SWITCHES FOR ACTIVE MODE FIG. 2 UPC20+ inoperative mode warning label 4 UPC20+ Universal Power Controller Product Information Control Options Modes If UPC20+ is powered up when changes are made to Dip Switch settings, then power must be cycled before changes can take effect. Motor Control mode The table list options and connections for motor control. DIP switch settings provide 1, 2 or 3 button remote control contact arrangements. In motor control mode, only one power relay (motor) can be energized at a time. When switching from one direction to another, the first motor is automatically turned off and a half-second delay is inserted before the other motor will turn on. Once a motor is turned on, it will automatically be turned off after the amount of time determined by the motor time delay potentiometer, R8. [. . . ] Terminal 1 is +12 VDC out, terminal 2 is serial data in, and terminal 3 is GND. The +12 VDC is short circuit protected, and the output supplies up to 25 mA for the remote sensor. For dual circuit 277 VAC operation, remove both 12 AWG wire jumpers. UPC20+ Universal Power Controller 13 Installation Installing the UPC20+ To install the UPC20+ unit: 1. Mount the UPC20+ on a wall or solid surface in the location where it will be used; it can be mounted either horizontally or vertically. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.