User manual ART MPA GOLD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ART MPA GOLD. We hope that this ART MPA GOLD user guide will be useful to you.


ART MPA GOLD : Download the complete user guide (296 Ko)

You may also download the following manuals related to this product:

   ART MPA GOLD DATASHEET (283 ko)

Manual abstract: user guide ART MPA GOLD

Detailed instructions for use are in the User's Guide.

[. . . ] 6 Meter Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Tube Warmth Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Front Panel Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Instrument Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Since it is single tuned, it preserves some low frequency content so its use is less obtrusive. Gain switch The Gain switch is used in conjunction with the input gain control to adjust signal levels through the MPA Gold. When depressed, the tube circuit provides 20dB more gain in the signal path. This also has the effect of driving the tube harder and making the tube the dominant source of gain and overload character. 5 ART MPA GoldTM Microphone Preamplifier 6 Phantom switch Phantom power on the microphone input is turned on and off with this switch. Depressing the switch will power condenser microphones and other 48volt phantom powered devices. NOTE: 1) Dynamic microphones are NOT affected by Phantom power, although it should be turned off when using dynamic microphones or line level inputs. 2) Although the 48volt phantom power ramps up and down slowly it may still create a pop. Mute the output of the MPA Gold when engaging or disengaging phantom power to prevent damage to equipment following the MPA Gold. Phase switch The Phase switch can invert the phase of the audio signal path in either channel. The Phase switch is located after the tube circuit in the signal path, so you can hear slight differences between different phase selections in the "normal" plate voltage mode near saturation. There are a number of reasons why adjusting the phase is needed these include, wiring errors and inversions in some audio equipment. If two microphones are out of phase, they may cancel at various frequencies (depending on the distance between them). If this happens, try changing the phase of one of the microphones and see if there is an improvement. Plate Voltage switch This switch sets both the tube bias point and the plate voltage level the balanced differential tube circuit runs at. The amount of headroom is adjusted by using the Gain switch and the input Gain control. The MPA Gold takes about 10-30 seconds to smoothly transition from one mode to the other. There is a slight increase in gain in the "High" plate voltage mode. 6 ART MPA GoldTM Microphone Preamplifier 7 In the "normal" (OUT) position, the tube distortion gradually rises until it smoothly clips. The tube is run almost completely open-loop in this mode, providing a musical tube "crunch" when overdriven with a natural recovery from clipping. The tube section can be more easily overdriven when the gain switch is in. This mode brings out the harmonics in the input sources, particularly stringed instruments. The tube circuit runs extremely clean in the "high" (IN) position of the plate voltage switch. As signal levels rise distortion remains very low until within 6dB of clipping, where the overload characteristics smoothly limit the signal swing. [. . . ] 2) If you find the unit to be at fault, write down a complete description of the problem, including how and when the problem occurs. Please write down a description of your complete setup before calling Customer Service. 3) Call the factory (585-436-2720) for a Return Authorization (RA) number. 5) Include with your unit: a return shipping address (we cannot ship to a P. O. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ART MPA GOLD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ART MPA GOLD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.