User manual BAUER SECCANT DATASHEET
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BAUER SECCANT. We hope that this BAUER SECCANT user guide will be useful to you.
Manual abstract: user guide BAUER SECCANTDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] the SeCCANt RANge
Regenerative dryer for air and gas
1500 3500 l/min 90 420 bar
EASY INTEGRATION B-CONTROL COMPRESSOR CONTROL OPTIONAL FILTER MONITORING GAS-TIGHT HELIUM CONSTRUCTION
Drying air and gases economically. This is the strong point of the SECCANT regenerative dryer from Bauer.
For dehumidifying and purifying air, nitrogen and rare gases, the SECCANT regenerative dryers offer a tailor-made system solution for every application. For solutions requiring absolute continuous operation, where the processes do not permit any interruption, can also be used in combination with a bypass filter system from BAUER. [. . . ] * 13 languages at present 2 the condensate separator removes condensed water and oil drops from the incoming flow of process gas/air. in left fig. ) at the same time as the second chamber is being regenerated (e. g. The regenerated gas/air is channelled through the charged adsorption medium and regenerates the absorber with the help of the partial decrease of line steam pressure. 4 the change-over module consists of main stream - as well as regeneration stream check valves and compensates the pressure between the drying chambers with a well designed change-over.
with activated carbon removes oil vapour and hydrocarbons from the process gas/air stream. The treated air corresponds in quality to pure air in accordance with DIN EN 12021. 6 the particle filter filters all particles from dried and deoiled gas. 7 the pressure maintaining valve guarantees, in the event of fluctuating final pressures, an optimal working pressure in the filter housing, allowing for an efficient absorption of the oil and water molecules.
1 B-CONtROL 2 CONdeNSAte SepARAtOR 3 dRyeR ChAmBeRS 4 ChANge-OveR mOdULe 5 pURifieR 6 pARtiCLe fiLteR 7 pReSSURe mAiNtAiNiNg
The quality seal of an original BAUER cartridge stands for purest breathing air acc. to DIN EN 12021.
vALve
BAUER KOMPRESSOREN
THE SEccanT RanGE
B-Control, the centre of communication
Continuous control maintains operational security B-CONTROL fully automatically monitors and controls all SECCANT`S internal functions like - Operating hours - Operating reports - SECURUS (optional) - Pressure dew point (optional) At the same time SECCANT`S B-CONTROL communicates with the compressor`s respective unit control: At start and stop the compressor unit sends SECCANT an On/Off signal. SECCANT permanently monitors itself during operation and sends the compressor a release signal. If a release signal is not received, the compressor is automatically stopped. If the compressor unit is equipped with a B-CONTROL EXTENDED control and connected to SECCANT via a CANBus, online control and online monitoring of SECCANT and the compressor unit can be realised via an external control room. As an SPC control B-CONTROL ensures the unit can be programmed according to customer requirements.
B-meSSeNgeR informs the operator online the unit operator via SMS on his/ her mobile phone, pager or via email about all important compressor data. the patented SeCURUS system (optional) reliably monitors the service life of the cartridge. This can only be achieved with a patented sensor technology, which is integrated in the filter cartridge. The integrated sensor indicates the necessity for cartridge change prematurely, warning in time about the exhaustion of the cartridge capacity and, finally switches the compressor off.
St co
2
SeCCANt 3 / 3A / 4 / 4A
THE SEccanT RanGE
BAUER KOMPRESSOREN
1 On/Off signal from the compressor unit to SeCCANt 2 Stand by report from SeCCANt to the compressor unit 3 Status report from SeCCANt to the B-CONtROL of the compressor unit 4 forwarding of operating reports by B-meSSeNgeR via fax, email or SmS
3
CAN-Bus
andard nnection
1
4
Compressur units with B-CONtROL Compressur units without B-CONtROL
BAUER KOMPRESSOREN
THE SEccanT RanGE
Custommade solutions with system engineering
the appropriate configuration for each purpose. The four models 3, 3A, 4 and 4A of BAUER`S SECCANT range offer a custommade system solution for dehumidification as well as purifying air, inert gases and noble gases. [. . . ] l/min / scfm Nominal pressure bar /psig dimensions D x W x H /cm Weight kg Air-/gas connection Ø mm Condensate connection Ø mm electric supply HZ /V Regeneration air/gas volume % of the compressor flow filter change intervals h pressure dew point °C particle size µm Residual oil content mg/m3 1500 /55 90-420 1300 - 6100 26 x 115 x 126 150 10 15
3
1500 /55
3A
3500 /129
4
3500 /129
4A
90-420 1300 - 6100 26 x 135 x 126 182 10 15
90-400 1300 - 5800 26 x 165 x 129 330 12 10
90-400 1300 - 5800 26 x 165 x 129 360 12 10
1phase 50/60 Hz 230 V / 400 V or 24 V DC 5 2000 -20 1 - 1) 5 2000 -20 1 < 0, 3 5 2000 -20 1 - 1) 5 2000 -20 1 < 0, 3
purification focus on:
Breathing air acc. to European Pharmacy Regulations
industrial air
industrial air acc. to DIN EN ISO 8573-1, Oil content class 3 Humidity class 3
Nitrogen / Rare gases
SECCANT 3 SECCANT 3A SECCANT 4 SECCANT 4A
required to fulfill the regulation
recommended
1) no oil removal
BAUeR KOmpReSSOReN gmbh P. O. Box 710260 | 81452 München Phone +49 (0) 89 / 7 80 49 - 0 Fax +49 (0) 89 / 7 80 49 - 167 info@bauer-kompressoren. de www. bauer-kompressoren. de
SeCCANt-e
9. 09 PR 0059 Subject to technical modifications [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BAUER SECCANT
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BAUER SECCANT will begin.