User manual DOMETIC DUO-THERM HP ROOF PARTS LIST
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC DUO-THERM HP ROOF. We hope that this DOMETIC DUO-THERM HP ROOF user guide will be useful to you.
Manual abstract: user guide DOMETIC DUO-THERM HP ROOFPARTS LIST
Detailed instructions for use are in the User's Guide.
[. . . ] - QUANTITY PART NUMBER - DESCRIPTION For Electric Details also state: VOLTAGE - WATTAGE
DUO-THERM HP Roof Mounted Heat Pump
530415. 501E1 530416. 501E1 530515. 501E1 530516. 501E1
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center Assistance Call: 800-544-4881
DUO-THERM HP Roof Mounted Heat Pump
With Solar Panel 530415. 506E1 530416. 506E1 530515. 506E1 530516. 506E1
Model Number 530415. 501E1 530415. 506E 1 530416. 501E 1 530416. 506E 1 530515. 501E 1 530515. 506E 1 530516. 501E1 530516. 506E1
PARTS LIST
Form No. [. . . ] 12 AWG Copper up to 24'
3. 5 KW / 5. 0 KW 3. 5 KW / 5. 0 KW 3. 5 KW / 5. 0 KW 3. 5 KW / 5. 0 KW
530416. 501 530416. 506
15, 000 15, 000
530515. 501 530515. 506 530516. 501 530516. 506 10. 3 10. 3 13. 2 13. 2 62. 0 62. 0 79. 0 79. 0 3. 0 3. 0 2. 8 2. 8 8. 5 8. 5 7. 6 7. 6 375 / 275 375 / 275 375 / 275 375 / 275 0. 55 / 1. 10 0. 55 / 1. 10 0. 70 / 0. 90 0. 70 / 0. 90 17. 5 17. 5 29. 5 29. 5 20 Amp 20 Amp 20 Amp 20 Amp
13, 500 13, 500 15, 000 15, 000
92 92 106 106
3. 5 KW / 5. 0 KW 3. 5 KW / 5. 0 KW 3. 5 KW / 5. 0 KW 3. 5 KW / 5. 0 KW
* **
***
For wire lenghts over 24 ft. Dometic Corporation gives GENERAL guidelines for generator requirements. These come from experiences people have had in actual applications When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power in high altitudes and from lack of maintenance. [. . . ] CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.
4
Wiring Diagram
530415 & 530416
530515 & 530516
530X1X. 50X Duo-Therm HP Parts List [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC DUO-THERM HP ROOF
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC DUO-THERM HP ROOF will begin.