User manual DOMETIC RM2193 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC RM2193. We hope that this DOMETIC RM2193 user guide will be useful to you.


DOMETIC RM2193 INSTALLATION: Download the complete user guide (249 Ko)

You may also download the following manuals related to this product:

   DOMETIC RM2193 PARTS LIST (365 ko)

Manual abstract: user guide DOMETIC RM2193INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] La Grange, IN 46761 Phone: 219 463 4858 I RECORD THIS INFORMATION FOR FUTURE REFERENCE BEFORE INSTALLING THE UNIT: Model No. Date Purchased Place of Purchase REFRIGERATOR MODEL RM 2191 & RM 2193 For Mobile Home or Recreational Vehicle Installation Operation by LP Gas, 12V DC or 120V AC FOR CHILD SAFETY CANADA Dometic Disk 866 Langs Dr. Cambridge, Ontario Canada N3H 2N7 Phone: 519 653 4390 FOR SERVICE CENTER ASSISTANCE CALL: 800 544 4881 DANGER: Risk of child entrapment. Before you throw away your old refrigerator: Take off the doors, leave the shelves in place, so that children may not easily climb inside. [. . . ] The liquid ammonia then flows into the evaporator (inside the freezer section) and is exposed to a circulating flow of hydrogen gas, which causes the ammonia to evaporate, creating a cold condition in the freezer. The tubing in the evaporator section is specifically sloped to provide a continuous movement of liquid ammonia downward by gravity through this section. If the refrigerator is operated when it is not level and the vehicle is not moving, liquid ammonia will accumulate in sections of the evaporator tubing. This will slow the circulation of hydrogen and ammonia gas, or in severe cases, completely block it, resulting in a loss of cooling. 2. CONTROLS The gas and electric controls are located at the rear of the refrigerator and are accessible through the lower vent in the outside wall of the vehicle. A B c D E F G = = = = = = = DC ON/OFF SWITCH GAS ON/OFF SAFETY VALVE PIEZO IGNITOR ELECTRIC THERMOSTAT AC ON/OFF SWITCH GAS INLET FITTING DC TERMINAL BLOCK FIG. LP GAS OPERATION After initial installation, servicing, or changing gas cylinders, etc. , the gas line may contain some air which should be allowed to escape by briefly turning on the refrigerator or other gas appliances. 8) If the ambient temperature is above 80°F and/or the door of the refrigerator is opened frequently the knob should be left in the "HIGH" position. 9) To terminate gas operation, turn knob (B) to the "OFF" position. 1) Open the shutoff valve of the gas bottle. Check that 2) 3) 4) 5) 6) 7) there is enough gas. Open any on-board shutoff valve which is in the gas line to the refrigerator. Open the lower vent at the rear of the refrigerator on the outside of the vehicle, and switch the electrical toggle switch/es (A in RM2191) and (A and E in RM2193) to the "OFF" position. Depress the knob (B) of the flame failure device. , and hold it down while depressing the piezo igniter button (C) several times in quick succession (a click should be heard each time it is depressed). Release the knob and check for flame by looking through the opening in the metal burner cover. If the burner fails to light within a couple of attempts, contact a qualified technician or your dealer. both gas and electricity at the same time. Always before using the alternate energy source. NOTE: The refrigerator has a flame failure device which will automatically shut off the gas to the burner if the flame is blown out. While the knob (B) is being held in, this device is temporarily inoperative. Most LP gas appliances used in recreational vehicles are vented to the outside of the vehicle. When parked close to a gasoline pump, it is possible that the gasoline fumes could enter this type of appliance and ignite from the burner flame, CAUSING A FIRE OR AN EXPLOSION. FOR YOUR SAFETY, it is recommended that all LP gas appliances which are vented to the outside should be shut off when refueling. The refrigerator must be shut off during refueling. The refrigerator is designed for the storage of fresh foods, milk, etc. Avoid using large dishes and do not stack food or food containers too closely as this interferes with the circulation of cold air within the cabinet. If possible, start the refrigerator on gas or AC the day before it is to be used, to allow time for the interior to be cooled. It is then preferable to load the refrigerator with food which has been precooled in your household refrigerator, or in the market. [. . . ] 3) To clean the burner, unscrew the screw (C) that fixes the burner on the boiler tube and be careful in order not to lose the washer. 5) To examine and eventually clean the burner jet, unscrew the gas pipe union (K) and pull out the burner jet (L). 6) Clean the jet by washing it in alcohol and blowing it through with air. NOTE: The jet fitted to this refrigerator is a size "45" which is suitable for use on propane gas at 11 inches water column. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC RM2193




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC RM2193 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.