User manual DOMETIC RM3962

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC RM3962. We hope that this DOMETIC RM3962 user guide will be useful to you.


DOMETIC RM3962 : Download the complete user guide (3400 Ko)

You may also download the following manuals related to this product:

   DOMETIC RM3962 PARTS LIST (431 ko)
   DOMETIC RM3962 INSTALLATION (3373 ko)

Manual abstract: user guide DOMETIC RM3962

Detailed instructions for use are in the User's Guide.

[. . . ] ® USER manUal REfRigERatoR foR lP-gaS & ElEctRic oPERation Rm3762 Rm3962 FOR YOUR SAFETY If you smell gas: 1. Immediately call your gas supplier. POUR vOTRE SécURITé Si vous sentez une odeur de gaz: 1. Avertissez immédiatement votre fournisseur de gaz. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. POUR vOTRE SécURITé Ne pas entreposer ni utiliser de l'essence ni d'autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil. !WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. [. . . ] shut off the refrigerator by pressing the main power ON/OFF button (OFF position). Leave the cabinet and freezer doors open and place the drip tray under the finned evaporator. Defrosting time can be reduced by filling the ice trays with hot water and placing them in the freezer compartment. CAUTION Do not use: · A knife or an ice pick, or other sharp tools to remove frost from the freezer shelves. Permanent damage could result from warping the metal or plastic parts. 4. Then, reset the thermostat to the desired setting, usually at mid setting. maintEnancE & SERvicE In order to keep the refrigerator working properly it is important that service is performed on a regular schedule. Please note that this service should be performed by qualified service personnel only!the information in this section is intended for service personnel. ElEctRic EqUiPmEnt heater The heat necessary for the operation of an absorption cooling unit is supplied by an electric heater mounted in a pocket of the boiler system. The refrigerator is equipped with one electrical heater for 120 V aC. fuses The refrigerator is equipped with 2 fuses - one for the refrigerator control system (3 a) and one for the aC heater (5 a). Replacing the fuses To replace the fuses, follow these steps: 1. Put back the power module cover. Replacing the heater To replace the heater, follow these steps: 1. With a pair of pliers, unfold the lug holding the lid of the boiler casing and then, open the lid. Close the lid of the boiler. -9- maintEnancE & SERvicE chEcking thE connEctionS LP gas is a flammable gas which has the potential to create a hazard. Do not smoke or create sparks when working on or near the LP gas system. (Blowing compressed air into the flue will not properly clean soot and scale out of the flue tube. ) 5. Before removing the burner jet: - Clean burner area of soot and scale that fell out of flue tube. Failure to heed this warning could cause an explosion resulting in death or severe personal injury. 1. The appearance of bubbles indicates a leak and should be repaired immediately! !Do not use a wire or pin when cleaning the burner jet as damage can occur to the precision opening. Failure to heed this warning could cause fire resulting in personal injury. chEcking thE contRol SyStEm Check the control system by connecting/disconnecting the 120V aC power, starting/stopping the engine, etc. chEcking thE lP gaS PRESSURE The LP gas pressure should be checked and the main regulator readjusted if the pressure is incorrect. Measure the LP gas pressure at the test port, just ahead of the burner jet. Ensure that the end of the burner fits into the slot on the burner bracket. Verify that the slots are centered under the flue tube and the thermocouple is positioned properly (tip of thermocouple extends over two slots of burner). THERMOCOUPLE gas equipment assembly SOLENOID VALVE . Check the electrode for proper location and gap. clEaning thE flUE bafflE and bURnER Inspect the flue baffle. [. . . ] This warranty is not extended by the length of time which you are deprived of the use of the product. Repairs and replacement parts provided under the terms of this warranty shall carry only the non-expired portion of this warranty. In no event shall either seller be liable for incidental or consequential damages. This includes any damage to another product or products resulting from such a defect. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC RM3962




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC RM3962 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.