User manual DOMETIC SI 1500 24V
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC SI 1500 24V. We hope that this DOMETIC SI 1500 24V user guide will be useful to you.
Manual abstract: user guide DOMETIC SI 1500 24V
Detailed instructions for use are in the User's Guide.
[. . . ] Welcome to the Dometic world Dometic Pure Sine wave Inverters A sign of comfort The SI 1500 Inverter is designed as a stand alone power inverter. this Inverter is extremely suitable for demanding RV , Commercial Vehicle , and Marine appliances. With its advanced power saving features you will enjoy the freedom mobile power wherever you go!Feel free to contact our dealers for more information or more recommendations within mobile power supply. [. . . ] Also, use only high quality copper wiring and keep cable length short, we recommend less than 3 meters / 10 feet. Failure to place an in-line fuse on the "+" cable running between the inverter and battery may cause damage to the inverter and will void warranty. Inverter Operation To operate the inverter, turn it on using the ON/OFF switch on the front panel. If you are operating several loads from the inverter, turn them on separately, one by one, after the inverter has been turned on. This will ensure that the inverter does not have to deliver the starting currents for all the loads at once and give you a problem free performance. At low input current, this voltage is very close to the battery voltage. At high input current, this voltage will be lower than the battery voltage because of the voltage drop across the cable and connections. Ideally, the voltage should remain in the green areas of the bar graph. If the voltage goes into the red area at top and bottom of the graph, inverter may shutdown. The AC load watt bar graph indicates the power drawn from the inverter. For long term operation, the watt indicator should remain in the green and orange area of the bar graph. If the watt indicator rises to high values the bar will flash and the inverter will shut down to protect itself. Over voltage indicator: The over voltage indicator indicates that the inverter has shut itself down because the maximum input voltage is exceeded. Under voltage indicator: The under voltage indicator indicates that the inverter has shut it self down because the input voltage is below the minimum level. Over temp indicator: The over temp indicator indicates that the inverter has shut itself down because the maximal temperature has been exceeded. The inverter may overheat because it has been operated at power levels above its rating, or because it has been installed in a location which does not allow it to dissipate heat properly. Overload indicator: The overload indicator indicates that the inverter has shut itself down because the output has been short circuited or drastically overloaded. Switch the ON/OFF switch to OFF, correct the fault condition, and then switch the ON/OFF switch back to ON to reset the unit. Power output The 1500W inverter will operate most AC loads within its power rating. When deeming whether a microwave oven can be operated by the 1500W inverter, remember that the power commonly advertised for microwave ovens are the cooking power (the power delivered to the food) not the power actually consumed by the microwave oven. The microwave oven will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the oven to determine its actual power requirements. [. . . ] After about 15 to 18 seconds after the green led has stopped flashing and become steady, output power will be available to the load. If the load is switched off, the output power will be shut down after about 15 to 18 seconds and the green led will start flashing with a flashing sequence of flash-flash-gap-flash-flash-gap. The front plate has a green led marked " power saving " for indication of enabled state of power save "sleep" mode (hereinafter referred to as the green led). The power saving "sleep " mode is disabled when the green led marked "power saving" is off. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC SI 1500 24V
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC SI 1500 24V will begin.