User manual GRASS VALLEY CONCERTO 1.7.6.1
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRASS VALLEY CONCERTO 1.7.6.1. We hope that this GRASS VALLEY CONCERTO 1.7.6.1 user guide will be useful to you.
Manual abstract: user guide GRASS VALLEY CONCERTO 1.7.6.1
Detailed instructions for use are in the User's Guide.
[. . . ] Concerto
ROUTING MATRIX
Instruction Manual
Software Version 1. 7. 6. 1
071813811 OCTOBER 2009
Affiliate with the N. V. KEMA in The Netherlands
CERTIFICATE
Certificate Number: 510040. 001 The Quality System of:
Thomson Inc, and it's wordwide Grass Valley division affiliates DBA GRASS VALLEY
Headquarters 400 Providence Mine Rd Nevada City, CA 95959 United States Kapittelweg 10 4827 HG Breda The Nederlands Rue du Clos Courtel CS 31719 35517 Cesson-Sevigné Cedex France 40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France Carl-Benz-Strasse 6-8 67105 Schifferstadt Germany 15655 SW Greystone Ct. Beaverton, OR 97006 United States 7140 Baymeadows Way Ste 101 Jacksonville, FL 32256 United States 1 rue de l'Hautil Z. I. des Boutries BP 150 78702 Conflans-Sainte Honorine Cedex France Spinnereistrasse 5 CH-5300 Turgi Switzerland 10 Presidential Way Suite 300 Woburn, MA 01801 United States 2300 So. [. . . ] A 15 pin D to 15 pin D cable.
See Figure 48 for cabling of a single non-redundant Crosspoint Bus Controller matrix.
Figure 48. Non-redundant Connection between Concerto and Jupiter
Concerto
MON IN MON OUT EXP IN 1 2 AUDIO/DATA TDM EXP OUT 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 18 14 10 6 2 28 24 20 16 12 8
1
2
32
30
28
24
20
16
12
8
4
30
26
22
18
14
10
6
4
2
MON IN
MON OUT EXP IN
INPUTS
25
21
17
13
9
5
1
31
27
23
19
15
11
7
OUTPUTS
22 AUDIO/DATA TDM
18
14
10
6
2
28
24
20
16
12
8
1
2 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1
1
2
EXP OUT
32
30
28
24
20
16
12
8
4
30
26
22
18
14
10
6
4
2
To Jupiter Control System
G
A 29 B
A 25 B
A 29 B
A 25 B
A 29 B
A 25 B
A 21 B
A 17 B
A 13 B
A 9B
A
B MON. OUT
1
2 A 30 B A 26 B A 30 B A 26 B A 22 B A 18 B A 14 B A 10 B A B
+
G+
EXP. IN
INPUTS
A 31 B A 27 B A 23 B A 21 B A 19 B A 17 B A 15 B A 13 B A 11 B A 9B A 7B A 3B A 31 B A 27 B A 23 B A 19 B A 15 B A 11 B A 7B A 5B
OUTPUTS
A 3B A 1B
A 32 B A 28
B A 24 B A 22
B A 20 B A 18
B A 16 B
A 14 B
A 12 B A 10
BA 8BA
4
B
A 32 B
A 28 B
A 24 B
A 20 B
A 16 B
A 12 B
A 8B
A 6B
A 3B
A
B
1
29
10 17
18 EXP. OUT 1 2
23
24
AES BALANCED BACKPLANE
21 22
3
4 11
12 19
20
INPUTS
EXP. IN
OUTPUTS
1
2
+
G+
G
MONITOR
5
6 13
14 21
22 25
26 29
30 31
32 3
47
8 11
12 15
16 19
20 27
28
31
32
IN OUT
XPT BUS
7
8 15
16 23
24 27
28
1
25
69
10 13
14 17
18 25
26
29
30
IN
OUT
36-60V
400W; 11. 1A
-
+
EXT COM 2 EXT COM 1
E-NET 2
E-NET 1
EXT COM
AES REF ALARM VID-REF 2 VID-REF 1
Terminator Thomson 9 pin D to 15 pin D Adaptor
AC PWR 1 100-240V
50/60Hz
AC PWR 2 500W; 5A
8138_03_95r1
90
Concerto -- Instruction Manual
Cabling A second Crosspoint Bus Controller module ordered to provide redundancy will include the following: · · A 9 pin D to 9 pin D cable (for pinouts see Table 35 on page 85), A 9 pin D to 15 pin D adaptor box, and
The adaptor box comes with a bracket that can be mounted in any of three positions on the box and is mounted on a rack support at the rear of the Concerto Matrix.
Note
XPT BUS
EXT COM
8138_03_96r1
·
A 15 pin D to 15 pin D cable.
See Figure 49 for cabling of a redundant Crosspoint Bus Controller matrix.
Figure 49. Redundant Connection between Concerto and Jupiter Control Frame
Concerto
MON IN MON OUT EXP IN 1 2 AUDIO/DATA TDM EXP OUT 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 18 14 10 6 2 28 24 20 16 12 8
1
2
32
30
28
24
20
16
12
8
4
30
26
22
18
14
10
6
4
2
MON IN
MON OUT EXP IN
INPUTS
25
21
17
13
9
5
1
31
27
23
19
15
11
7
OUTPUTS
22 AUDIO/DATA TDM
18
14
10
6
2
28
24
20
16
12
8
1
2 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1
1
2
EXP OUT
32
30
28
24
20
16
12
8
4
30
26
22
18
14
10
6
4
2
To Jupiter Control System
G
A 29 B
A 25 B
A 29 B
A 25 B
A 29 B
A 25 B
A 21 B
A 17 B
A 13 B
A 9B
A
B MON. OUT
1
2 A 30 B A 26 B A 30 B A 26 B A 22 B A 18 B A 14 B A 10 B A B
+
G+
EXP. IN
INPUTS
A 31 B A 27 B A 23 B A 21 B A 19 B A 17 B A 15 B A 13 B A 11 B A 9B A 7B A 3B A 31 B A 27 B A 23 B A 19 B A 15 B A 11 B A 7B A 5B
OUTPUTS
A 3B A 1B
A 32 B
A 28 B
A 24 B
A 22 B
A 20 B
A 18 B
A 16 B
A 14 B
A 12 B
A 10 B
A
8B
A
4B
A 32 B A 28 B A 24 B A 20 B A 16 B A 12 B
A8B
A6B
A3B
A2B
Terminator
1
29
10 17
18 EXP. OUT 1 2
23
24
AES BALANCED BACKPLANE
21 22
3
4 11
12 19
20
INPUTS
OUTPUTS
EXP. IN
1
2
+
G+
G
MONITOR
5
6 13
14 21
22 25
26 29
30 31
32 3
47
8 11
12 15
16 19
20 27
28
31
32
IN OUT
XPT BUS
XPT BUS
7
8 15
16 23
24 27
28
1
25
69
10 13
14 17
18 25
26
29
30
IN
OUT
36-60V
400W; 11. 1A
-
+
EXT COM 2 EXT COM 1
E-NET 2
E-NET 1
EXT COM
AES REF ALARM VID-REF 2 VID-REF 1
0. 3 m (1 ft) Thomson 9 pin D to 15 pin D Adaptors
EXT COM
AC PWR 1 100-240V
50/60Hz
AC PWR 2 500W; 5A
8138_03_96r1
Concerto -- Instruction Manual
91
Section 2 -- Installation
Ethernet Communications
Ethernet is used for communication between the Concerto and either an Encore or SMS 7000 Control System frame. Communications can be established using either E-NET 1 (to communicate with the Controller in slot 1) or E-NET 2 (to communicator with the Controller in slot 2). One connection can be used as a primary connection and the other can be used as a redundant connection. Network Connection between Concerto and Control Frame
Concerto
MON IN MON OUT EXP IN 1 2 AUDIO/DATA TDM EXP OUT 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 18 14 10 6 2 28 24 20 16 12 8
To Control Frame
6 4 2
1
2
32
30
28
24
20
16
12
8
4
30
26
22
18
14
10
MON IN
MON OUT EXP IN
INPUTS
25
21
17
13
9
5
1
31
27
23
19
15
11
7
OUTPUTS
22 AUDIO/DATA TDM
18
14
10
6
2
28
24
20
16
12
8
1
2 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1
1
2
EXP OUT
32
30
28
24
20
16
12
8
4
30
26
22
18
14
10
6
4
2
A 29 B
A 25 B
A 29 B
A 25 B
A 29 B
A 25 B
A 21 B
A 17 B
A 13 B
A 9B
A
B MON. OUT
1
2 A 30 B A 26 B A 30 B A 26 B A 22 B A 18 B A 14 B A 10 B A B
+
G+
G
EXP. IN
INPUTS
A 31 B A 27 B A 23 B A 21 B A 19 B A 17 B A 15 B A 13 B A 11 B A 9B A 7B A 3B A 31 B A 27 B A 23 B A 19 B A 15 B A 11 B A 7B A 5B
OUTPUTS
A 3B A 1B
A 32 B
A 28 B
A 24 B
A 22 B
A 20 B
A 18 B
A 16 B
A 14 B
A 12 B
A 10 B
A
8B
A
4B
A 32 B A 28 B A 24 B A 20 B A 16 B A 12 B
A8B
A6B
A3B
A2B
1
29
10 17
18 EXP. OUT 1 2
23
24
AES BALANCED BACKPLANE
21 22
3
4 11
12 19
20
INPUTS
OUTPUTS
EXP. IN
1
2
+
G+
G
MONITOR
Managed Ethernet Switch
5
6 13
14 21
22 25
26 29
30 31
32 3
47
8 11
12 15
16 19
20 27
28
31
32
IN OUT
7
8 15
16 23
24 27
28
1
25
69
10 13
14 17
18 25
26
29
30
IN
OUT
36-60V
400W; 11. 1A
-
+
EXT COM 2 EXT COM 1
E-NET 2
E-NET 1
AES REF ALARM
VID-REF 2
VID-REF 1
AC PWR 1 100-240V
50/60Hz
AC PWR 2 500W; 5A
8138_00_18r1
References
Concerto requires a Video Reference. Most composite analog video sync signals will work with the exception of 4 Volt and 2 Volt discreet sync signals. To allow time stamped deterministic switching, the Video Reference must contain an embedded Vertical Interval Time Code (VITC) signal. The AES sync reference loop-thru input provides a 48 kHz formatted signal for re-synchronization to frame and block boundaries. The signal is required for the Analog Audio and the Digital Audio (AES) modules to function properly. [. . . ] Commonly used in telecommunications to connect computers and terminals to modems and other devices. The C suffix refers to the version of the RS-232 standard.
Remote
Remote is used during configuration to identify remote Sources and Destinations. Remote Sources and Destinations are inputs and outputs not physically connected to the System using the related configuration file. These remote Sources and Destinations are controlled over a network.
RS-485
A high-speed serial interface connection between data communications equipment. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GRASS VALLEY CONCERTO 1.7.6.1
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRASS VALLEY CONCERTO 1.7.6.1 will begin.