[. . . ] 1.
Loosen screws holding thermostat to subbase, wallplate, to wall and lift away. As you disconnect each wire, use masking tape to label it with the old terminal designation. Wrap wires around a pencil to keep them from falling back into the wall as shown in Fig. 2.
WIRES THROUGH WALL OPENING
CROSS-RECESSED SCREWDRIVER
HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED TO DRILL HOLES IN WALL
WIRE CUTTER/STRIPPER OR SHARP KNIFE, IF NEEDED TO STRIP WIRES
MASKING TAPE, IF NEEDED TO LABEL WIRES AS DISCONNECTED FROM OLD THERMOSTAT
M5136
Fig. [. . . ] Level for appearance only; the thermostat functions properly even when not level. CT2700 wiring diagram, 2-wire, heat-only system.
T8700
M12532
R G Y W FAN COIL
1 L1 (HOT) L2 1 24V
COOLING CONTACTOR COIL
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
M12544
Fig. IMPORTANT Use 18-gauge maximum wire to wire the thermostat.
3
69-1085
CT2700 AN ELECTRONIC ROUND TM PROGRAMMABLE THERMOSTAT
All wiring must comply with local electrical codes and ordinances. If unsure about household wiring procedures, call your local heating and air conditioning contractor. Refer to the masking tape labels you placed on wires when you removed your old thermostat. Match the letter of your old thermostat wire with the terminal of the corresponding letter on your new thermostat. 7.
ROUTE WIRING AS SHOWN THROUGH ENTRANCE HOLE ALTERNATE MOUNTING SCREW HOLE
5 ADJUST FAN OPERATION SWITCH
The thermostat fan operation switch, labeled fuel switch in Fig. If this system is an electric heat system, set the switch to the E (electric) position. The E setting allows the fan to turn on immediately with the heating or cooling equipment in a system where the G terminal is connected.
FUEL SWITCH
AT HE
FA N
FF O
ON
MOUNTING SCREW HOLE
F
E
CO OL
TO AU
R G Y W
ALTERNATE MOUNTING SCREW HOLE MOUNTING SCREW HOLE WIRING ENTRANCE HOLE
M12529
M12531
Fig. NOTE: To ensure proper mounting of the thermostat, restrict all wiring to the left side of the terminals. Loosen the terminal screws and slip each wire beneath its matching terminal. The shape of the terminals permit insertion of straight or wraparound connections. Tighten the terminals.
6 MOUNT THERMOSTAT TO
WALLPLATE
Align the tab and connector pins at the top of the thermostat with the wallplate. 10.
DASHED LINES INDICATE TABS ON BACK OF THERMOSTAT
HE
AT
FA N
O
CO OL
FF
ON
TO AU
Set
CO OL
HE
AT
FA N
FOR WRAPAROUND, STRIP 7/16 INCHES (11 mm)
O
FF
ON
TO AU
A ALIGN TABS/PINS AT TOP
FOR STRAIGHT INSERTION, STRIP 5/16 INCHES (8 mm)
OF THERMOSTAT WITH WALLPLATE CONNECTOR.
Set
M12537
Fig. Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation.
B
M12530
PRESS THERMOSTAT CASE STRAIGHT ON TO LATCH.
Fig. Mounting thermostat to wallplate.
69-1085
4
CT2700 AN ELECTRONIC ROUND TM PROGRAMMABLE THERMOSTAT
Press the thermostat straight on to the wallplate to latch. NOTE: To remove the thermostat from the wallplate, grasp the thermostat on both sides and pull the thermostat straight out. The thermostat then displays the current time and room temperature.
AM
PM
7 PROGRAM YOUR THERMOSTAT
The thermostat is preprogrammed for your convenience with the following time and temperature settings, see Table 2. Preprogrammed Time/Temperature Settings.
PM
Period WAKE SLEEP
Start Time 6:00 AM
Heating Setpoint 70°F (21°C)
Cooling Setpoint 78°F (25. 5°C) 82°F (28°C)
10:00 PM 62°F (16. 5°C)
WAKE is the time period you want the house at a comfortable temperature during the day. SLEEP is the time period you can set for an energysavings temperature while you are sleeping. The following sequence uses the heating program as an example; the System switch is in the HEAT position. [. . . ] Honeywell shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting, directly or indirectly, from any breach of any warranty, expressed or implied, or any other failure of this product. Some states do not allow the exclusion or limitation or incidental or consequential damages, so this limitation may not apply to you. This warranty is the only expressed warranty Honeywell makes on this product. The duration of any implied warranties, including the warranties of merchantability and fitness for a particular purpose is hereby limited to the one year duration of this warranty. [. . . ]