[. . . ] PROGRAMMABLE THERMOSTAT
OWNER'S GUIDE
Seven Day Programmable Heat Pump Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3611 Para pedir estas instrucciones en español, llame al 1-800-468-1502. Pour obtenir ce ode demploi en français, composer le 1-800-468-1502.
Honeywell CT3611
Table of Contents
Step 1. Prepare for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remove Old Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] --The program period when you want the house at a comfortable temperature for activities before bedtime. Return (This is a higher temperature during the heating season and a lower temperature during the cooling season). --The program period you can set for an energy-saving temperature while you are sleeping. (This is a lower Sleep temperature during the heating season and a higher temperature during the cooling season).
69-1081--3
12
Table 2 can be helpful when planning your schedule of time and temperature settings. Period Wake Default Setting Time (6:00AM) Heata (70°F/21°C) Coolb (78°F/25. 5°C) Leave Time (8:00AM) Heata (62°F/16. 5°C) Coolb (85°F/29. 5°C) Return Time (6:00PM) Heata (70°F/21°C) Coolb (78°F/25. 5°C) Sleep Time (10:00PM) Heata (62°F/16. 5°C) Coolb (82°F/28°C)
a Your b
Monday (Mon)
Tuesday (Tue)
Wednesday Thursday (Wed) (Thu)
Friday (Fri)
Saturday (Sat)
Sunday (Sun)
heating setpoints cannot be higher than 90°F (32°C) or lower than 40°F (4. 5°C). Your cooling setpoints cannot be higher than 99°F (35°C) or lower than 45°F (7°C).
Program the First Day
Start by programming the wake time and temperature for one day. q q q Press and release Press
Day Wake
.
until the desired day displays. (Mon, Tue, Wed, Thu, Fri, Sat, Sun) or until the desired time shows in the display. 13 69-1081--3
Press time
NOTE: q Press
Program times are in 15 minute intervals. or until the desired wake temperature displays.
The setpoint temperature range is 40°F to 90°F (7°C to 31°C) for heating and 45°F to 99°F (9°C to 37°C) for cooling. q Press
Heat/Cool Settings
to switch between setpoints.
NOTE: q q q Press Press
Program times are the same for heating and cooling. or
Leave
until the display shows the desired temperature setpoint. ,
Return
or
Sleep
and repeat these steps for each program period. The first day is now programmed.
Repeat each step in Program the First Day for the rest of the week. After the first day is programmed, you can copy that day to any other day using procedure in Copy a Day.
Run Program
NOTE: q Press
when the entire week is programmed.
Copy a Day
Your thermostat can copy program settings from one day to another. q q q Press Press Press
Wake
,
Leave
,
Return
or
Sleep
to enter programming mode.
Day
until the display shows the day you want to copy. The display shows.
Mon
Copy
M13327
q
Press
Day
until the display shows the day you want to copy to.
Mon Wed
M13328
69-1081--3
14
q q
Press
Copy
to accept the change.
Repeat these steps for each day you want to copy. donE appears for two seconds and then the normal program display appears.
M13329
NOTE:
Clear a Program Period
NOTE: q q q q q Press Press Wake cannot be cleared.
Leave
,
Return
, or
Sleep
for the program period you want to clear.
Day
until the desired day displays.
Leave
Press and hold the
,
Return
, or
Sleep
for approximately 3 seconds until the time and temperature clear.
Repeat the above steps for each period to be cleared. OPERATING YOUR THERMOSTAT
Change Temperature Setting Until the Next Program Period (Temporary Change)
q Press or until the screen shows the desired temperature setting. NOTE: The temporary temperature setting is displayed for about 3 seconds and then the room temperature is displayed. The setting cancels when the next program period starts or when you press
Run Program
.
15
69-1081--3
Change Temperature Setting Indefinitely (Hold)
q q q Move the System switch to the desired position (Heat or Cool). (The display changes from showing the setpoint temperature to room temperature after approximately three seconds). [. . . ] 66°F · Your CT3611 thermostat learns from Recovery experience. Each day it checks how Begins 1 closely it hit the recovery target and then 64°F adjusts the next day's recovery start System Operating in Energy Savings Mode time accordingly. 62°F · It takes a few days after installation for the thermostat to adjust to the local 5:00 5:30 6:00 6:30 weather, your lifestyle, the construction ENERGY COMFORT RECOVERY FROM ENERGY SAVINGS SAVINGS PERIOD of your home, and your heating/cooling PERIOD TIME system. THERMOSTAT USES THE SAME SCHEME TO RETURN TO LOWER COMFORT TEMPERATURE DURING THE COOLING SEASON. [. . . ]