[. . . ] PROGRAMMABLE THERMOSTAT
OWNER'S GUIDE
Seven Day Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT8602 Para obtener un documento con las instrucciones en español, por favor visite nuestro sitio de web a: www. honeywell. com/yourhome. Pour obtenir des notices techniques en français, veuillez consulter notre site web: www. honeywell. com/yourhome.
Honeywell CT8602
Table of Contents
Step 1. Prepare for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remove Old Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Press Time
to return to main display.
11
69-1532--2
Time Format (Feature Number 16)
Time format options are: -- 0 = 12-hour clock (preset). Press Time
to return to main display.
Heating Temperature Range Stops (Feature Number 34)
Temperature range options are: -- 90 = highest setting for heating setpoint (preset). -- 40 to 89 = temperature range (1°F increments) of heating setpoint settings. Press or until the display shows the desired heating temperature range stop. Press Time to move to next feature or Program to return to main display.
M18748
Cooling Temperature Range Stops (Feature Number 35)
Temperature range options are: -- 45 = lowest setting for cooling setpoint (preset) -- 46 to 99 = temperature range (1°F increments) of cooling setpoint settings. Press or until the display shows the desired cooling temperature range stop. Press Time to move to next feature or Program to return to main display.
M18749
Factory Set Function (Feature Number 37)
Do not change this setting. Press Time to move to next feature or
Run Program
to return to main display.
M18754
69-1532--2
12
Furnace Air Filter Timer (Feature No. 43)
Filter timer options: 0 = off 1 = 30 days 2 = 90 days (preset) 3 = 180 days 4 = 365 days To change your filter timer: !Press Time NOTE: to move to next feature or
Run Program
M19600
to return to main display.
The filter time is based on calendar days.
Humidifier Pad Timer (Feature No. 44)
Humidifier pad timer options: 0 = off (preset) 1 = 90 days 2 = 180 days 3 = 365 days To change your humidifier pad timer: !Press Time NOTE:
to return to main display.
The humidifier pad time is based on calendar days. See your humidifier instructions for complete details on replacing and/or cleaning your humidifier pad.
Ultraviolet (UV) Lamp Timer (Feature No. 45)
UV lamp timer options: 0 = off (preset) 1 = 365 days To change your UV lamp timer: !Press Time NOTE:
to return to main display.
The UV lamp time is based on calendar days. See your UV lamp instructions for complete details on replacing your UV lamps. Press On initial power-up, the screen flashes 1:00 pm until you press a key.
Set Curent Day/Time Day
. Press
Daylight Time Run Program
advances time in one-hour increments. )
until "DST" displays if daylight savings time is in effect. The thermostat displays day, time, program period, temperature, system and fan settings. There is an individual key for each of the four program periods: --
Wake
--The program period when the house is at a comfortable temperature while you get ready for work or
school. (This is a higher temperature during heating season and a lower temperature during cooling season. ) --
Leave
--The program period you can set for an energy-saving temperature while you are away at work or school.
(This is a lower temperature during heating season and a higher temperature during cooling season. ) --
Return
--The program period when you want the house at a comfortable temperature for activities before bedtime.
(This is a higher temperature during heating season and a lower temperature during cooling season. ) --
Sleep
--The program period you can set for an energy-saving temperature while you are sleeping. (This is a lower
temperature during heating season and a higher temperature during cooling season. ) 69-1532--2 14
-- Table 2 shows the default temperature settings. [. . . ] · · Wait until Replace Battery indicator is illuminated and replace batteries. Replace batteries now.
Thermostat backlight appears dim.
Toll-Free Customer Assistance
Please read and follow the instructions for this thermostat. If you have questions about this thermostat, visit our web site at www. honeywell. com/yourhome, or call Honeywell Customer Care at 1-800-468-1502.
21
69-1532--2
WIRING DIAGRAMS
2-WIRE HEAT-ONLY (JUMPER INTACT)
THERMOSTAT B RC O W Y R G R
4-WIRE HEAT/COOL (JUMPER INTACT)
THERMOSTAT B RC O W Y G
HEATING RELAY OR VALVE COIL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
1
HEATING RELAY OR VALVE COIL
COOLING CONTACTOR COIL
FAN RELAY
1
M10616
1 POWER SUPPLY. [. . . ]