User manual HONEYWELL HS 30
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL HS 30. We hope that this HONEYWELL HS 30 user guide will be useful to you.
Manual abstract: user guide HONEYWELL HS 30
Detailed instructions for use are in the User's Guide.
[. . . ] For information on how the device switch can be used for the thermostat control, read from Page 18. For information on how the device switch can be used for the boiler request, read from Page 14. The switch module is designed for surface mounting on a distribution box of the device circuit. [. . . ] The Teach-in mode can be aborted by pressing the button at the switching module briefly. LED display at the switch module during the Teach-in Display LED flashes red LED blinks red LED off LED lights up red with short breaks Meaning Teach-in not carried out Teach-in mode (duration 4 minutes) Teach-in successful Teach-in failed
8
Teach-in
Assignment to Hometronic Manager HCM 200
Switching to "Settings" submenu of Hometronic Manager The Hometronic Manager is in automatic mode. The display* at the Hometronic Manager HOMETRONIC shows the standard display (example): WE 29. 10. 1999 11:15 No Lifestyle active LIVING 20. 0 C
Press the Dial button.
The cursor* flashes in the lowest line.
HOMETRONIC WE 29. 10. 1999 11:15 No Lifestyle active LIVING 20. 0 C LIFESTYLE TIME PROGRAMS DISPLAY SETTINGS INSTALLATION DE-INSTALLATION FUNCTION EXTENSION SENSOR FUNCTION
Turn the Dial button to the right until
"Menu" is selected. The following text is displayed:
Turn the Dial button to the left until
"Settings" is selected. The following text is displayed:
The Hometronic Manager is in the "Settings" submenu.
9
Teach-in
Assigning device switch HS 30 to Hometronic Manager as a device
In the following example a humidifier is assigned to the switch module. Turn the Dial button until "Installation" HEATING/COOLING is selected. DEVICES/LIGHT The following text is displayed: SENSOR
Turn the Dial button to the left until
the "Devices/Light" selected:
Press the Dial button.
submenu
is
HEATING/COOLING SHUTTERS DEVICES/LIGHT SENSOR MODULE-1 MODULE-2 HUMIDIFIER CEILING LIGHT
The module names are displayed.
Turn the Dial button to the left until
the corresponding module selected, e. g. : "Humidifier".
is
MODULE-1 MODULE-2 HUMIDIFIER CEILING LIGHT
10
Teach-in
Press the Dial button.
An * appears after the "Humidifier" module.
MODULE-1 MODULE-2 HUMIDIFIER CEILING LIGHT
*
Activate Teach-in mode at the socket switching module within four
minutes (see Chapter "Activating the Teach-in mode at the switch module" on Page 8). If "Q" is displayed after a module name, this module has already been assigned to the Hometronic Manager. The process of assigning or changing module names is described in the operating instructions of the Hometronic Manager.
Installing device switch HS 30 at Hometronic Manager as a collection relay of thermostat control
Installation of the collection relay (HS 20 or HS 30) has no effect on the maximum number of devices at the Hometronic Manager HCM 200. Change to the "Settings" submenu as described on Page 9.
11
Teach-in
Turn
the Dial button until "Installation" is selected. The following text is displayed:
Turn the Dial button to the left until
HEATING/COOLING SHUTTERS DEVICES/LIGHT SENSOR SENSOR SETPOINT ADJUSTER ROOM CONTROL BOILER REQUEST SWITCHING MODULE ANTI-FREEZE SENSOR THERMOSTAT SWITCHING MODULE ANTI-FREEZE SENSOR THERMOSTAT SWITCHING MODULE ANTI-FREEZE SENSOR THERMOSTAT
"Boiler request" is selected.
Press the Dial button.
The following text is displayed:
Turn the Dial button to the left until
"Thermostat" is selected.
Press the Dial button.
An "*" appears after the "Thermostat" entry. The device switch is assigned.
*
The socket switching module HS 30 is installed as a collection relay.
12
Teach-in Uninstalling collection relay Change to the "Settings" submenu (refer to Page 9). Turn the Dial button until "De- HEATING/COOLING SHUTTERS Installation" is selected. SENSOR The following text is displayed:
Turn the Dial button to the left until
"Boiler request" is selected.
SENSOR SETPOINT ADJUSTER ROOM CONTROL BOILER REQUEST SWITCHING MODULE ANTI-FREEZE SENSOR THERMOSTAT SWITCHING MODULE ANTI-FREEZE SENSOR THERMOSTAT SWITCHING MODULE ANTI-FREEZE SENSOR THERMOSTAT * * * *
Press the Dial button.
The following text is displayed:
Turn the Dial button to the left until
"Thermostat" is selected.
Press the Dial button.
The "*" after the "Thermostat" entry disappears. The collection relay is uninstalled.
13
Teach-in
Installing device switch HS 30 at Hometronic Manager for boiler request (HK 10)
Installation of the collection relay (HS 20 or HS 30) has no effect on the maximum number of devices at the Hometronic Manager HCM 200.
Connect the switch module to the cable of the boiler control (refer to
Page 5).
Activate the Teach-in at the switch module (refer to Page 8). Change to the "Installation" submenu at the Hometronic Manager
(refer to Page 8).
Turn the Dial button to the left until
the "Boiler demand" menu item is selected. [. . . ] The collection relay is switched off again if all of the room setpoint temperatures are below the boiler setpoint. For information on installing and setting the thermostat control, refer to the operating instructions of the Hometronic Manager HCM 200.
18
Appendix
Appendix
Glossary
Automatic mode Standard operating mode of the Hometronic Manager. Boiler demand Signal that the Hometronic Manager sends to the heating boiler when the setpoint drops below the minimum value. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL HS 30
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL HS 30 will begin.