User manual HONEYWELL SDC
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL SDC. We hope that this HONEYWELL SDC user guide will be useful to you.
You may also download the following manuals related to this product:
HONEYWELL SDC (3684 ko)
HONEYWELL SDC MANUAL 2 (533 ko)
HONEYWELL SDC QUICK GUIDE (528 ko)
HONEYWELL SDC INSTALLATION INSTRUCTIONS (3684 ko)
Manual abstract: user guide HONEYWELL SDC
Detailed instructions for use are in the User's Guide.
[. . . ] Heating Controller SDC Remote Heating Controller DHC
OPERATING INSTRUCTIONS
EN2H-0220GE51 R0308
EN2H-0220GE51 R0308
SDC / DHC
Contents
Contents
1 2 Software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2. 1 2. 2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Requirements for start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] HEATING operating mode remains active until another operating mode is activated. Activated continuous lowering operation appears in the basic display with the information RED. HEATING.
Display
Pos: 18 /156-Honeywell/Bedienung/Standby-Betrieb @ 1\m od_1207644379916_6. doc @ 9420
4. 1. 2. 5. 7
Standby mode In standby mode, the entire system is switched off and protected from frost (all frost-protection functions active).
C
Hot-water production is disabled and protected from frost. Application Total deactivation of heating and hot water with full building protection. The heat generator and hot-water production remain in operation in case of external demand or demand by other heating circuits on the bus network. The heating circuit pumps are switched on briefly every day (pump anti-blocking protection). The standby mode remains active until another operating mode is activated. Display Activated continuous standby mode appears in the basic display with the information STANDBY.
NOTE
Pos: 19 /156-Honeywell/Bedienung/Taste_Schaltzeiten_Urlaubsprogramm e @ 1\mod_1207830153957_6. doc @ 10720
4. 1. 2. 6
"Switching time programs / Holiday programs" button Using this button, you can create individualised switching time programs for heating and hot-water operation and set holiday mode. 34.
Pos: 20 /156-Honeywell/Bedienung/Urlaubsbetrieb @ 1\m od_1207644072619_6. doc @ 9315
EN2H-0220GE51 R0308
23
Operation
SDC / DHC
4. 1. 2. 6. 1
Holiday mode In holiday mode, the heating circuits can be switched off and protected from frost or operated based on the settings for the RED. HEATING operating mode for the duration of the holiday based on the presetting ("Direct circuit" or "Mixed heating circuit 1" / "Mixed heating circuit 2" menu, parameter 25 = holiday operating mode).
Setting
Press button. The menu-selection level Switching time programs / Holiday programs appears in the display. You can now enter additional holiday timeframes (up to 15 holiday blocks).
Application
Longer absence while heating operation is active.
24
EN2H-0220GE51 R0308
SDC / DHC
Operation
Control during holidays
At outside temperatures below the frost-protection limit (see 4. 2. 3 "System Parameters" menu, pg. 51) the heating circuits are controlled as follows: Without wall devices: Based on a lowered room temperature specification of 3 C. With wall devices: Based on the room frost-protection limit of the respective heating circuit of 10 C (see "Direct Heating Circuit" or "Mixed Heating Circuit 1", "Mixed heating circuit 2" menu, parameter 08 = room frost-protection limit).
Cancellation
An active holiday program can be cancelled in case of early return. (current date + 250 days) An active holiday program appears in the basic display with information on the return date.
Pos: 21 /156-Honeywell/Bedienung/Taste_Anlageninform ation @ 1\m od_1207644494728_6. doc @ 9450
EN2H-0220GE51 R0308
25
Operation
SDC / DHC
4. 1. 2. 7
"System information" button Calls up system information, such as temperatures and counter data. The information on the outside temperature appears first after the
button is pressed. Turning the input button causes the
system temperatures and the counter and consumption states and operating states of the connected system components to appear. Pressing the input button causes the respective setpoint values to appear. Exceptions Collector flow temperature: Solar tank temperature: Outside temperature: NOTE No setpoint No setpoint Averaged value
The displayed information (see the following example) is independent of the installed or enabled system components and control circuits.
26
EN2H-0220GE51 R0308
SDC / DHC
Operation
Operating overview
Press Turn input button to the left
button Turn input button to the right
Average/current outside temperature value
Program/operating mode direct heating circuit/pump status
Outside temperature min. (0:00 to 24:00 hours)
Program/operating mode mixed heating circuit 1/pump status
Heat generator temperature setpoint/actual value
Actuator of mixed heating circuit 1/status
Hot-water temperature setpoint/actual value
Program/operating mode mixed heating circuit 2/pump status
Flow temperature setpoint/actual value
Actuator of mixed heating circuit 2/status
Flow temp of mixed heating circuit 1 setpoint/actual value
Program/operating mode hot-water circuit/pump status
Flow temp of mixed heating circuit 2 setpoint/actual value
Heat generator status
Variable input 1 setpoint/actual value
Direct heating circuit pump function/status
Variable input 2 setpoint/actual value
Variable output 1 function/operating state
Variable input 2 setpoint/actual value
Variable output 2 function/operating state
Operating hours
Activations of heat generator
EN2H-0220GE51 R0308
27
Operation
SDC / DHC
Setting time for automatic return
If the button is pressed and held for approx. With this parameter, the time it takes for automatic return to the basic display can be specified.
Setting range
OFF
No return. The last selected information display continuously remains in the basic display until the next change. [. . . ] Legionella protection is activated on the selected day of the week at the legionella protection time set in the following parameter. The legionella protection function is activated daily at the legionella protection time set in the next parameter.
ALL
56
EN2H-0220GE51 R0308
SDC / DHC
Operation
NOTE
If a hot-water thermostat (see 05 parameter = transducer for hotwater circuit) is used to detect the hot-water temperature, these parameters are skipped.
Pos: 55 /156-Honeywell/Bedienung/Menues_Direkheizkreis_Mischheizkreis @ 1\m od_1207647253025_6. doc @ 9975
4. 2. 5
"Direct Heating Circuit" / "Mixed Heating Circuit 1" / "Mixed Heating Circuit 2" menu These menus contain all parameters required to program the heating circuit, except the switch time programs. one direct heating circuit and two mixed heating circuits (mixed heating circuit 1 and mixed heating circuit 2) are available as heating circuits. The following described heating circuit parameters are available separately for setting for each heating circuit.
Pos: 56 /156-Honeywell/Bedienung/Reduzierter_Betrieb @ 1\mod_1207647295322_6. doc @ 9990
4. 2. 5. 1
Reduced operation During reduced operation, you can select between two operating modes.
Factory setting Setting range Set values
ECO ECO, RED RED (lowering operation) The heating circuit pump of the direct heating circuit continues functioning during reduced operation (see 4. 2. 3. 2 Time program, pg. [. . . ]