FEATURES
· Typically used in buildings (including: restaurants, shopping malls, office buildings and banks) under 55, 000 square feet. [. . . ] NOTE: This is further modified by selection of conventional or electric heat.
4 63-2604
PROGRAMMING
The thermostat operates at the Occupied temperature setting unless the thermostat is programmed. The thermostat can be set for two Occupied and two Not Occupied times for each day of the week (28 independent time settings). The Temporary Occupied key provides quick setpoint changes for increased comfort during Not Occupied periods. The Temporary Not Occupied key provides energy efficient operation for extended periods of time.
IMPORTANT Programming the thermostat with the keypad requires 24 Vac (turn on system power). NOTE: Before starting programming, use Table 2 to organize the program schedule.
Setting Current Day/Time
This can be done using the keypad. IMPORTANT Once you set the day/time once, you should not need to set it again. As a result, if you use a PDA to set the day based upon the calendar (MM/DD/ YYYY), the device will not allow the keypad to change the day.
5 63-2604
Table 2. Day Monday Tuesday Wednesday Thursday Friday Saturday Sunday NOTE: 12:00 PM is Noon, and 12:00 AM is Midnight.
6 63-2604
Occupied Period 1
Not Occupied Period 1
Occupied Period 2
Not Occupied Period 2
Temperature
Occupied
HEAT COOL
Set Day/Time
Day Time
Override
Temporary Temporary Occupied Not Occupied
Not Occupied
HEAT COOL
Day
Clear Occupied Not Occupied Start Time
Schedule
System Copy
HEAT COOL
Fan
ON AUTO
Run Schedule
M19610BB
Fig. NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday, Wed = Wednesday, Thu = Thursday, Fri = Friday, Sat = Saturday. 4.
7
Press Run Schedule.
63-2604
Setting Schedule Times
Use the keys in the "Schedule" area of the keypad for this procedure. Repeat steps 2 through 5 until finished.
NOTE: The thermostat must be in program mode to use the copy feature. NOTE: DONE displays for two seconds then the program display reappears. 8.
8
Copying a Day
Use the keys in the "Schedule" area of the keypad for this procedure.
Repeat steps 2 through 6 for all the days desired. Press Occupied or Not Occupied until the start period to be cleared is displayed. [. . . ] Press to display the default setpoint.
Changing Temperature Setpoint Until Next Program Period
1. The temporary temperature appears for approximately ten seconds, then the room temperature is displayed.
NOTE: The only way to change this setpoint is to change the Not Occupied setpoint.