[. . . ] Change the Operating Mode of Heating/Cooling Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Change the Operating Mode of Ventilation Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Change the Time and Day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 3 3 4 5 5 6 7 8 9 10
i
69-0860--1
T7525/T7526 THERMOSTAT TOUCHPAD
69-0860--1
TOUCHPAD SCREENS
T7525/T7526 THERMOSTAT TOUCHPAD
WHAT YOU CAN DO USING THE TOUCHPAD
Using the T7525/T7526 Thermostat Touchpad, you can easily adjust your energy management heating/cooling system to keep your home comfortable, and at the same time, conserve energy and lower your utility bills. [. . . ] If either setpoint is adjusted into the deadband, the other setpoint will automatically change to maintain the minimum 3 degree F differential.
M4469
First Options Menu
Set: C: 80 o Warmer Actual: 80 o Cooler Change Heat 12:25PM Mon Next
Back Select
Step 4
Second Options Options Menu
Select
4. If you press the Options or Next soft key or do not press a key for one minute, the change will also be accepted. The screen displays the actual temperature and the heating/cooling setpoint. NOTE: To accept the temporary setpoint change and perform another function, press the Options soft key. The new temperature setting remains in effect until the next scheduled period or, if so configured, when the unit price rate changes.
Hold Temperature More
Back
M8626A
Step 4
Options Run Schedule Climate Control Present Time/Day
Back Select
The new temperature setting remains in effect until the next scheduled period or, if so configured, when the utility price rate changes. The temporary change can be canceled and the system returned to the original setpoint temperature by pressing the Run Schedule soft key in the second Options menu.
Base Screen
More
M8627A
69-0860--1
4
USING THE TOUCHPAD
T7525/T7526 THERMOSTAT TOUCHPAD
Hold the Temperature
Base Screen
Set: C: 80 o Warmer Actual: 80 o Cooler
Back
Step 1
Select
You can hold the current setpoint temperature until you manually cancel it. The screen displays the actual temperature and the heating/cooling setpoint. The hold remains in effect until you manually cancel it.
Rate: NORMAL Options 12:25PM Mon Next
M8625A
First Options Menu
Options
Step 2
Select
Hold Temperature More
Back
M8626A
Cancel the Temperature Hold
Base Screen
Hold: C: 80 o Warmer Actual: 80 o Cooler
Back
Step 1
Select
You can cancel the temperature hold. The screen displays the actual temperature and the heating/cooling setpoint.
Rate: NORMAL Options 12:25PM Mon Next
M4470
First Options Menu
Options
Step 2
Select
or a. The screen displays the actual temperature and the heating/cooling setpoint.
Cancel Temperature Hold More
Back
M4471
Second Options Menu
Options Run Schedule Climate Control Present Time/Day More
Step 2
Select
Back
M8627A
5
69-0860--1
T7525/T7526 THERMOSTAT TOUCHPAD
USING THE TOUCHPAD
Change the Program Setpoint Temperatures
Base Screen
Set: C: 80 o Warmer Actual: 80
o
Step 1
Select
You can change the setpoint temperature. Press the or soft key repeatedly until the desired selection (Weekday, Saturday, or Sunday) displays. The screen displays the current settings for each period for the selected day. NOTE: H refers to the heating setpoint; C refers to the cooling setpoint. Press the Change Heat or Change Cool soft key until the desired setpoint type (Heat or Cool) is displayed.
Cooler
Back
Rate: NORMAL Options 12:25PM Mon Next
M8625A
First Options Menu
Options
Step 2
Select
Hold Temperature More
Back
M8626A
Second Options Menu
Options Run Schedule Climate Control Present Time/Day More
Step 3
Select
Back
M8627A
Climate Control Menu
Climate Control Settings and Schedules Heat/Cool Equipment Ventilation
Step 4
Select
9. Press the or soft key repeatedly until the desired temperature setting displays. The setpoint temperature range is 45° to 88°F (7° to 31°C). To accept the new setting, press the Select key or do not press a key for one minute. To cancel the temperature entered in step 9, press the Back key within one minute. The screen displays the current settings for the selected day.
Back
M8628A
b.
Settings and Schedules Menu
Settings and Schedules Weekday
Step 5
Select
Temperature Settings Day Schedule
Back
NOTE: For systems using the T7525C/T7526C Thermostat Touchpads (auto changeover), a minimum 3 degree F (2 degree C) deadband is maintained between the heating and cooling setpoints. If either setpoint is adjusted into the deadband, the other setpoint will automatically change to maintain the minimum 3 degree F differential.
M8629A
11. Repeat steps 7 through 10 for any other heating or cooling setpoints that need to be changed. Press the Select key repeatedly until the Base screen displays.
Current Settings Screen
Sunday Settings Wake Leave Return Sleep H: 70° C: 78° H: 62° C: 78° H: 70° C: 78° H: 64° C: 78°
Steps 6 & 7
Select
Back
M4472
Current Period Settings Screen (Change Cool Shown) Steps 8-10
Weekday-Leave Settings Heat: 62 o
Select
Back
Change Cool
M8630A
69-0860--1
6
USING THE TOUCHPAD
T7525/T7526 THERMOSTAT TOUCHPAD
Change the Time a Period Starts
Base Screen
Set: C: 80 o Warmer Actual: 80
o
Step 1
Select
You can change the time a period starts. [. . . ] Press the Next Field soft key repeatedly until the Day field is highlighted. Press the or soft key repeatedly until the desired day displays.
Back
b.
Steps 4 & 5
Present Time + Day 8:35AM Monday Next Field Auto Set
M8633A
5. Perform one of the following:
Select
a.
To accept the changes, press the Select key. NOTE: The time and day displayed at the Touchpad can be restored to the utility time and day by pressing the Auto Set soft key in the Present Time + Day screen. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL T7525