[. . . ] Compact control units ZG 215N / 215 VN / 252 N
MOUNTING INSTRUCTIONS
Mounting of the Control Unit
It can be mounted in any dry room, e. Maximum permissible ambient temperature: 45 C.
Door Mounting
The casing cover is held by a snap hinge closure. [. . . ] Pull the controller insert out of the casing with the aid of the slide on the instructions case.
Press the left lock pin to the left with a screwdriver; by doing so, the case is freed from the device's base. Mount the device's base with two 0. 4 mm screws and dowels horizontally on the wall.
The assembly is to be carried out in the opposite order.
Electrical Connections
The electrical connections are to be carried out by a technician!
n Left terminal strip (base):
Cross sections
230 V AC 1. 5 mm (connection to the control unit, servomotor, pump) 18 V DC >= 0. 75 mm (connection to the sensors and selectors) The 18 V lines are to be laid separately from the 230 V lines. Use shielded cables in the presence of intense HF disturbance fields!
sing of this device model. floor heating) an additional thermostat is recommended to provide separate over-temperature limitation. With 230 V/50 Hz the servomotor and circulation pump require the jumper from terminal 5 to 6. The local regulations on earthing and resetting are to be followed carefully when connecting the device. Earlier temperature selector and sensor versions without additional letters A (e. TW 20, RF 20, TF 20, etc. ) have the same electrical connections and the same resistance values as the device versions with with additional letter A.
n Right terminal strip (base):
Wiring
The single accessory parts are to be connected according to the wiring diagram on the back of the ca-
Noise suppression
Our control units are all provided with noise suppression.
n Before putting the system into service, check
Checking the Control System
whether the control device is connected as illustrated in the wiring diagram.
Checking the Temperature Sensors and -Selectors
n The servomotor's sense of rotation can be deter-
mined by setting the control unit's operating mode selector on "auto" for ZG 252N or "auto" for ZG 215N / ZG 215VN and by changing the room target value on setting knob B (ZG 252N) or on the TW/TF (ZG 215N / ZG 215VN). LED Display Red Green Servomotor Opens Closes
By measuring the resistance it can be checked whether the temperature sensors and selectors are connected correctly. (The indicated terminal numbers refer to the markings on the sensors and selectors. )
Temperature Sensor AF20, VF 20, VF 20A
Resistance values (R) at ambient temperature (t) t [C] -20 -10 0 +20 +25 +30 +70 +90 R [kW] 220 122 70 25 20 16 3, 1 1, 5
Setting knob B or TW / TF Turn towards + Turn towards
Temperature Selector TW 20A, TF 20A
Setting on the Selector Resistance [kW] between the terminals 1/2 Right stop (+12) Left stop (-12) 147 100 1/3 100 147 2/3 47 47
If the sense of rotation is wrong, invert terminals 10 and 11 on the left-hand of the terminal strip.
Connecting the Potentiometer
If a potentiometer is used as feedback with the ZG 215N instead of the flow sensor VF 20, also terminals 4 and 5 on the right-hand are to be inverted besides terminals 10 / 11 if the sense of rotation of the actuator (mixer, ventilation valves), is wrong. When opening the actuator the resistance between terminals 3 / 4 of the motor must be lower, while the resistance between terminals 4 / 5 of the motor amounts always to 10 kW.
Temperature Selectors TF 22 and TFU 22
Setting on the selector Resistance [kW] between terminals1 / 3 auto Right stop (+7) Left stop (-7) 28. 7 69. 8 day 4, 8 13. 8 night 0 0
Temperature Selectors TW 21A. . . TW 23A
Setting on the Selector Resistance [kW] between the terminals 1/2 TW 21A (-15. . +15C) TW 22A (0. . . +30 C) TW 23A (20. . +70 C) 35 58 26 1/3 45 68 27 2/3 10 10 9
Pump Activation in the ZG 215N
If no heat input is required, the circulation pump can be switched off by means of an auxiliary switch in the motor. [. . . ] 12
1 2 3 4 5 6 7 8 9 10 11 12
123 PE NL
1 2 3 4 5 6 7 8 9 10 11 12
Operating instructions ZG 252NV EN-2H0215 GE51 ZG 215NV EN-2H0216 GE51 ZG 215VN EN-2H0217 GE51 "Informationsschrift" (Planning broschure in German) L3 Comfort-Kompakt-Regler GE-0H 0327 GE51
CB50247F
VF
AF
ext. 123456 10 9
Hometronic
ALTERNATIVE
ALTERNATIVE
TF 22 7 12 10 7 5
HCE 60 12 4
5678 1234
123456 U+ TFU 22
[CBZG_MAE. VP]
TW 20
HCM 200
Hometronic
Centra Regelungstechnik Honeywell AG Bblinger Strae 17 D 71101 Schnaich Telefon +49 (70 31) 637-01 Telefax +49 (70 31) 637-493
EN 1H-0181 GE51 R1001
07157 562
http://www. honeywell. de/hga [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL ZG252N