[. . . ] INSTRUCTION MANUAL
VHF MARINE TRANSCEIVER
iM35
DOC
CE versions of the IC-M35 which display the "CE" symbol on the serial number seal, comply with the essential requirements of the European Radio and Telecommunication Terminal Directive 1999/5/EC. This warning symbol indicates that this equipment operates in non-harmonised frequency bands and/or may be subject to licensing conditions in the country of use. Be sure to check that you have the correct version of this radio or the correct programming of this radio, to comply with national licensing requirement.
DECLARATION OF CONFORMITY
We Icom Inc. Japan
1-1-32, Kamiminami, Hirano-ku Osaka 547-0003, Japan Declare on our sole responsability that this equipment complies the essential requirements of the Radio and Telecommunications Terminal Equipment Directive, 1999/5/EC, and that any applicable Essential Test Suite measurements have been performed. [. . . ] to activate the volume mute function.
· The volume level is set to the minimum level (OFF). · The volume level indicator blinks.
w Push [VOL/SQL MONI] again to exit the squelch adjustment mode.
Indicates the squelch level. Blinks while adjusting the squelch level.
w Push [LOUD MUTE] again, or push [VOL/SQL MONI] to turn the volume mute function OFF.
12
BASIC OPERATION
4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Lock function
This function electronically locks all keys (except for [PTT], [VOL/SQL MONI], [LOUD MUTE], [Hi/Lo ] and [Y]/[Z]*) to prevent accidental channel changes and function access. to turn the lock function ON and OFF.
Appears while the lock function is activated.
Automatic backlighting
This function lights the function display and keys, and it is convenient for night-time operation. 19) Push any key except for [PTT] to turn the backlight ON.
· The backlight is automatically turned OFF after 5 sec. of inactivity.
AquaQuake water draining function
The AquaQuake water draining function clears water away from the speaker grill. Without this function, water may muffle the sound coming from the speaker. The transceiver emits a vibrating beep when this function is activated. Push and hold both [SCAN DUAL] and [Hi/Lo ].
· A low beep tone sounds for 9 sec. · The transceiver never accepts key operation while the AquaQuake function is activated. · The AquaQuake function can not be activated when an optional speaker-microphone is connected.
Push and hold for 1 sec.
Monitor function
The monitor function opens the squelch. 19) The monitor function is activated by pushing and holding [VOL/SQL MONI] for 1 sec.
·" " blinks and the squelch is opened. Blinks while the monitor function is activated.
Push and hold for 1 sec.
13
5
SCAN OPERATION (Except Holland version)
Scan types
Scanning is an efficient way to locate signals quickly over a wide frequency range. In addition, the auto scan function is available for standby convenience. This function can be activated depending on the setting in the set mode. 18) PRIORITY SCAN
CH 01 CH 02
Set the TAG channels (scanned channels) before scanning. Clear the TAG for unwanted channels which inconveniently stop scanning, such as those for digital communications. 15) Choose the desired scan type from "Priority" or "Normal" in the set mode. 18) NORMAL SCAN
CH 01 CH 02
CH 88
CH 16
CH 03
CH 88
CH 03
CH 05
CH 04
CH 05
CH 04
Priority scan searches through all TAG channels in sequence while monitoring Channel 16. When a signal is detected on Channel 16, scan pauses until the signal disappears; when a signal is detected on a channel other than Channel 16, scan becomes Dualwatch until the signal disappears.
Normal scan, like priority scan, searches through all TAG channels in sequence. However, unlike priority scan, Channel 16 is not checked unless Channel 16 is set as a TAG channel.
14
SCAN OPERATION
5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Setting TAG channels
For more efficient scanning, add the desired channels as TAG channels or clear TAG for unwanted channels. TAG channels can be assigned to each channel group (U. S. A. , International and ATIS) independently. [. . . ] NOTE: The microphone is located at the top of the speaker-microphone, as shown above. To maximize the readability of your transmitted signal (voice), hold the microphone approx. NOTE: When the speaker-microphone is connected to the transceiver, the noise cancellation does not work.
Attaching: Attach the [SP MIC] cap (q), then rotate it clockwise completely (w). 3
PROBLEM
The transceiver does not turn · The battery is exhausted. [. . . ]