[. . . ] Application Note:
NED YH5000B
Camera Descriptions
· · · · ·
Interfacing non-standard cameras to Matrox Pulsar January 17, 1997
5000 x 1 x 8-bit Line scan camera Fixed line scan Analog video output Digital RS-422 hsync and pclk 2 modes of operation: fixed line scan rate (Camera master, Pulsar master)
Interface Modes Camera Interface Briefs
·
Mode 1: Fixed line scan rate (Camera master)
Video
NED YH5000B
CMCLK HSYNC
Matrox Pulsar Matrox Pulsar
· · · · · · · ·
5000 x 1 x 8-bit Analog video output DCF configured for 512 lines per virtual frame Line scan rate is fixed at 1. 9802 kHz with a pixel clock frequency of 10 MHz Exposure time is inversely proportional to line scan rate Continuous video Matrox Pulsar receiving Video, CMCLK, and HSYNC signals from camera DCF used: YH5B_L. DCF
Mode 2: Fixed line scan rate (Pulsar master)
Video
NED YH5000B
CMCLK HSYNC
Matrox Pulsar
· · · · · · · ·
5000 x 1 x 8-bit Analog video output DCF configured for 512 lines per virtual frame Line scan rate is fixed at 1. 9802 kHz with a pixel clock frequency of 10 MHz Exposure time is inversely proportional to line scan rate Continuous video Matrox Pulsar sending CMCLK and HSYNC signals to camera DCF used: YH5B_LM. DCF
Cabling Requirements
Mode 1: Fixed line scan rate (Camera master)
·
Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO BNC of the camera.
Application Note:
NED YH5000B
Cabling Requirements (continued) )
·
Interfacing non-standard cameras to Matrox Pulsar January 17, 1997
The connections between the DB-15 female connector of the camera and the DB-37 male connector of the PLS-TTL-CABLE are as follows:
PLS-TTL-CABLE (DB-37 male connector) Pin name Pin no. [. . . ] The connections between the DB-15 female connector of the camera and the DB-37 male connector of the PLS-TTL-CABLE are as follows:
PLS-TTL-CABLE (DB-37 male connector) Pin name Pin no. CLKOUT05 HSYNC+ 16 CLKOUT+ 24 HSYNC34 Camera Control Box (DB-15 female connector) Pin name CLOCKSTART+ CLOCK+ START-
·
Pin no. 10 04 03 11
·
Other connections are required between the camera and the camera control box. Refer to the camera manual for details.
The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp. matrox. com). Please verify all interface connections with camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.