Detailed instructions for use are in the User's Guide.
[. . . ] Operating and installation instructions
Cooker hoods DA 406 DA 407 DA 409 DA 409 EXT
To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed or used for the first time.
GiWOZH
M. -Nr. 29 Operation with Control module DSM 400 Connection to a window contact switch . 34
2
Caring for the environment
Disposal of the packing material
The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and can normally be recycled. cling film, polystyrene) and plastic wrappings must be kept out of the reach of babies and young children. [. . . ] The indicator lamp will go out.
14
Operation
Filter operating hours counter
The number of hours the appliance has been in operation is stored in memory. Reading the filter operating hours counter The indicator lamp for the grease filter touch control will come on after 30 hours of operation. After the filters have been replaced, the filter operating hours counter must be reset. ^ To do this, press and hold the grease filter touch control for about 3 seconds. For recirculation mode, the operating hours counter for the charcoal filter needs to be set to the required time (see "Setting and altering the charcoal filter operating hours counter"). To check the percentage of time set already used:
^ Press the On/Off touch control to switch the fan on.
^ Press and hold the grease filter or the charcoal filter touch control.
One or more of the indicator lamps for the " / +" touch controls will flash. The number of flashing lamps shows the percentage of the operating time which has already been used up.
The indicator lamp for the charcoal filter touch control will light up after the cooker hood has operated for the number of hours set. After the charcoal filter has been replaced, the filter operating hours counter must be reset.
1 lamp 2 lamps 3 lamps 4 lamps
= 25 % = 50 % = 75 % = 100 %
The number of operating hours used remains in the memory, even when the appliance is switched off or there is a power cut.
15
Operation
Filter operating hours counter You can set the operating hours counter to suit the type of cooking you do. If you only cook occasionally we recommend that you still select a short time, because grease which has built up gradually over a long period of time will harden on the grease filter and make cleaning more difficult. Altering the grease filter operating hours counter The operating hours counter for the grease filters is set at 30 hours. The time set can be lengthened or shortened: you can choose 20, 30, 40 or 50 hours. If you do not confirm your selection within 4 minutes, the cooker hood will automatically revert to the "old" data. The indicator lamp for the grease filter touch control and one of the " / +" touch control lamps will flash. The " / +" control lamps show the time which has been set: 1st lamp from the left = 20 hours 2nd lamp from the left = 30 hours 3rd lamp from the left = 40 hours 4th lamp from the left = 50 hours ^ Use the " / +" touch controls to select the desired time.
^ Press the run-on option touch control and the grease filter touch control at the same time.
16
Operation
Setting and altering the charcoal filter operating hours counter (with recirculation mode) The charcoal filter is needed for recirculation mode. On delivery, the operating hours counter for the charcoal filter is set to unlimited. For recirculation mode, the operating hours counter needs to be set to the required time: The " / +" control lamps show the time which has been set: 1st lamp from the left = 120 hours 2nd lamp from the left = 180 hours 3rd lamp from the left = 240 hours 4th lamp from the left = unlimited ^ Use the " / +" touch controls to select the desired time.
^ Press the On/Off touch control to switch the fan off.
^ Confirm the selection by pressing the charcoal filter touch control. If you do not confirm your selection within 4 minutes, the cooker hood will automatically revert to the "old" data.
^ Press the run-on option touch control and the charcoal filter touch control at the same time. The indicator lamp for the charcoal filter touch control and one of the lamps above the " / +" touch controls will flash.
17
Cleaning and care
Avoid: Before carrying out any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Ensure that: it is switched off at the wall socket and the plug withdrawn, or the fuse is withdrawn from the fused spur connection unit, or the mains fuse is withdrawn, or the screw-out fuse is removed (in countries where this is applicable). cleaning agents containing soda, acids, chlorides or solvents, abrasive cleaning agents, e. g. powder cleaners or cream cleaners and abrasive sponges, as well as pot scourers or sponges which have been used previously with abrasive cleaning agents. Important for appliances with stainless steel housing (This infomation does not apply to the controls). [. . . ] If the control module is disconnected in order to operate the cooker hood without the window contact switch (e. g. after moving house) the cooker hood electronics must be reset by a Miele service technician.
Potential free connection This enables an external appliance to be controlled according to the switch setting on the cooker hood fan. For instance it can be used to ensure a sufficient supply of fresh air when the cooker hood and a heating appliance which also depends on the air in the room are being used together, by switching on an air intake fan, or opening a motorised inlet flap as soon as the cooker hood fan is switched on. It is important to ensure that the fan power is sufficient and that the air intake has a suitable cross-sectional diameter. [. . . ]