User manual MIELE DG 4064 L

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DG 4064 L. We hope that this MIELE DG 4064 L user guide will be useful to you.


MIELE DG 4064 L : Download the complete user guide (339 Ko)

Manual abstract: user guide MIELE DG 4064 L

Detailed instructions for use are in the User's Guide.

[. . . ] The stopcock for the steam oven water inlet must be located so that it is easily accessible after the appliance has been built in. To ensure that the waste water is pumped away completely, the mains drainage outlet point should not be positioned higher than the drain hose outlet position on the steam oven. The hoses and mains connection cable must be fitted in such a way that the appliance can be easily taken out of the housing unit by a service technician should repair work ever be necessary. This steam oven must only be installed in a suitable tall housing unit. The appliance must be installed at such a height that small children cannot reach the appliance door, which gets hot during use. [. . . ] c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!h Drain hose Important: The top end of the drain hose i must not be higher than 500 mm where it connects to the odour trap. 11 Appliance and building-in dimensions DG 4064 L and AB 45-7 in 450 mm tall housing unit 45 2 200 cm 595 05 55 448-452 324 b fg 56 8 0-56 593-595 378 385 55 270 5 95 05 55 8 54 c d e h 5 56 60- 1 22 59 54 500 4 59 22 5 i 12 700 a 552 63 65 Appliance and building-in dimensions a Cut-out in the housing unit for feeding the water inlet and outlet hoses through b Isolator switch position. c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!h Drain hose Important: The top end of the drain hose i must not be higher than 500 mm where it connects to the odour trap. 13 Installation Building in and connecting to services ^ Before connecting the appliance to the mains supply you must disconnect the electricity supply to the isolator switch. ^ Connect the mains connection cable to the isolator switch in accordance with current local and national safety regulations. ^ Feed the water inlet and drainage hoses through the cut-out a in the housing unit. ^ Push the appliance into the recess as far as it will go, making sure that the mains connection cable and the water inlet and drain hoses do not get trapped or damaged when doing so. ^ Secure the appliance using screws j supplied, as shown in the diagrams. ^ Using the Operating Instructions as a guide, check all oven functions are working correctly. Before using for the first time, check all hose connections for leaks. DG 4064 DG 4064 L 14 Electrical connection All electrical work should be carried out by a suitably qualified and competent person, in strict accordance with current local and national safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous. Ensure power is not supplied to the appliance until after installation or repair work has been carried out. Do not connect the appliance to the mains electricity supply by an extension lead. Connection should be made via a suitable isolator which complies with national and local safety regulations, and the On/Off switch should be easily accessible after the appliance has been built in. If the switch is not accessible after installation (depending on country) an additional means of disconnection must be provided for all poles. For extra safety it is advisable to install a residual current device (RCD), with a trip current of 30 mA. When switched off there must be an all-pole contact gap of at least 3 mm in the isolator switch (including switch, fuses and relays). The appliance is supplied for connection to a 230-240 V, 50 Hz supply with a 3-core cable. The wires in the mains lead are coloured in accordance with the following code: Green/yellow = earth Blue Please make sure that the connection data quoted on the data plate match the household mains supply. [. . . ] If a water softener is already installed in the building, the electrical conductivity of the water must be maintained. The hose may be lengthened up to a maximum of 7. 5 metres using hose extensions. These are available as optional accessories from the Miele Spare Parts Department, and must not be shortened or damaged. Please note: If the hose is lengthened, the hose extension does not have a solenoid valve. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DG 4064 L




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DG 4064 L will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.