User manual PARADOX 646 KEYPAD
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PARADOX 646 KEYPAD. We hope that this PARADOX 646 KEYPAD user guide will be useful to you.
Manual abstract: user guide PARADOX 646 KEYPAD
Detailed instructions for use are in the User's Guide.
[. . . ] To create or modify access codes, follow the steps indicated in section 2. 2. The master code and user codes are identified by a 2 digit "code number".
2. 2 CREATING USER CODES
1) Press [ENTER] and then enter your master code (default 474747) or user 1 code. You will hear the "confirmation" beep and the [ENTER] key will flash. Enter the two digit "code number" (01-48) for the user code you wish to program (or 00 to change the master code). [. . . ] Press [BYP] in Step 2 (see above) and the previous bypass status will be re-established.
3. 9 FORCE (AWAY) ARMING
To arm the system rapidly without waiting for the Esprit Keypads 9
"READY" light (for all zones to close), use Force "Away" arming. Open zones will not be protected, but will be armed as soon as they are closed.
How do I Force Arm the system?The [AWAY] key will flash.
3. 10 ARMING BOTH SYSTEMS SIMULTANEOUSLY
If your code has access to both systems:
How do I Arm Systems A and B simultaneously?The "ready" light will also begin to flash and the exit timer will begin to countdown.
3. 11 ARMING SYSTEM A AND B SEPARATELY
If your Access Code has access to System A:
How do I arm System A?The "ready" light will also begin to flash and the exit timer will begin to countdown.
If your Access Code has access to System B:
10 User's Manual
How do I arm System B?The "ready" light will also begin to flash and the exit timer will begin to countdown.
3. 12 STAY ARMING SYSTEM A
Please refer to section 3. 3 on page 7 for an explanation of stay arming. With your system partitioned, only System A will be Stay armed when the [STAY/11] key is pressed.
3. 13 "NO MOVEMENT" SUPERVISION FEATURE
Your panel can be programmed to send a report and/ or arm the system if it is not armed and there is no zone activity for a preprogrammed amount of time.
3. 14 AUTOMATICALLY ARM ON TIME
Your installer can program your system to arm at a specific time each day. In this mode, all protected zones and detection devices must be in the "normal" state before arming can occur.
Esprit Keypads 11
3. 15 DISARMING
How do I Disarm the Security System?The "armed" light will go off and the keypad will stop beeping.
3. 16 DISARMING SYSTEM A AND B SEPARATELY
If your Access Code has access to System A:
How do I Disarm System A?The "armed" light will go off and the keypad will stop beeping.
If your Access Code has access to System B:
How do I Disarm System B?The "armed" light will go off and the keypad will stop beeping.
12 User's Manual
3. 17 VIEWING ALARM MEMORY
The memory light [MEM] on your keypad will illuminate if any alarm situations take place while your system is armed. After disarming the system, pressing once on the [MEM] key brings up the zones that were open during the last alarm period.
4. 0 PANIC ZONES
The Esprit provides three "panic" zones on your keypad. These panic zones can generate audible or silent alarms, both of which also can be sent directly to your central security station. The 3 different panic zones can also communicate specific messages to your monitoring station, i. e. Ask your installer for the exact definition of your panel's panic alarms.
4. 1 "PANIC 1" - PANIC ALARM
Pressing keys [1] and [3] simultaneously for 2 sec. will generate a "panic 1" or a "panic alarm".
4. 2 "PANIC 2" - AUXILIARY ALARM
Pressing keys [4] and [6] simultaneously for 2 sec. will generate a "panic 2" or an "auxiliary alarm".
Esprit Keypads 13
4. 3 "PANIC 3" - FIRE ALARM
Pressing keys [7] and [9] simultaneously for 2 sec. will generate a "panic 3" or a "fire alarm".
5. 0 KEY ACCESS PROGRAMMING
Several control panel features can be programmed quickly on the keypad. The Security Company or installer may ask you to perform some of these functions. To enter the One-key Access programming mode:
How do I enter One-key Access programming mode?3) Then press the key that corresponds to the feature you wish to activate (see below). 4) Press [ENTER] or [CLEAR] to exit.
Key [9]
Feature Description "Auto-arming" Time Programming: When the [9] key flashes, enter the time using the 24-hour clock (ex: 6PM would be entered as 18:00). [. . . ] 20 User's Manual
Your installer can advise you of the best way to test your particular system.
9. 1. 2 Fire Alarm Testing
CAUTION: Do not use open flame or burning materials to test your fire detection devices. Contact your alarm installer to discuss safe methods to test your system.
10. 0 SYSTEM CHECKLIST
10. 1 PANIC BUTTONS
Keys [1] and [3] Panic Alarm Type
!"Silent !"Silent !"Silent
Police or ______________________ !"Audible"""""!"Not Used Auxiliary or ____________________ !"Audible"""""!"Not Used Fire or ________________________ !"Audible"""""!"Not Used
[4] and [6]
[7] and [9]
10. 2 ZONE CHECKLIST
Is this a partitioned system?System A =___________System B =____________
Esprit Keypads 21
Zone # and Description
01: 02: 03: 04: 05: 06: 07: 08: 09: 10: 11: 12:
System AB "!""!"!""!
Zone # and Description
13: 14: 15: 16: 17: 18: 19: 20: 21: 22: 23: 24:
System AB "!""! [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PARADOX 646 KEYPAD
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PARADOX 646 KEYPAD will begin.