Detailed instructions for use are in the User's Guide.
[. . . ] makes no warranty, expressed or implied, including but not limited to any implied warranties or merchantability or fitness for a particular purpose, regarding these materials and makes such materials available.
CONTENTS
COPYRIGHT CONTENTS DISPLAY AND KEYBOARD OPERATION KEY FUNCTION KEY DISPLAY COMBINATION OF MODE A OR MODE B ALPHANUMETRIC INPUT 1. INTRODUCTION 1. 1 Introduction 1. 2 Before using the PowerTopoLite manual ACCESSING POWERTOPOLITE 2. 1 How to access PowerTopoLite 2. 2 Allocation of each PowerTopoLite Function key 2. 3 Typical Function keys of PowerTopoLite FILE MANAGER 3. 1 Information of the remaining memory available 3. 2 Creation of a new Job 3. 3 Selection of a Job name 3. 3. 1 Selection of a Job 3. 3. 2 Selection by a Job name input 3. 4 Deletion of a Job name 3. 4. 1 Deletion from a Job list 3. 4. 2 Deletion from a Job name search 3. 5 All Clear MEASURE 4. 1 Station setup [By Rectangular Coordinates] 4. 1. 1 Point name, PN, input 4. 1. 2 Coordinates, X, Y, Z, IH, and PC input 4. 2 Station Orientation 4. 2. 1 Station orientation 4. 3 Measuring 4. 4 Point Code 4. 5 Remote, Offset, Station, and H. angle 2 3 6 6 7 9 9 10 10 11 13 13 15 17 18 18 19 20 20 21 22 22 23 24 25 26 27 27 32 33 34 35 38 38 40 42 42
2.
3.
4.
3
4. 6 Station setup [ By Polar Coordinates] 4. 6. 1 Point name, PN, input 4. 6. 2 IH, TEMP, PRESS, ppm and PC input 4. 7 Station Orientation 4. 8 Measuring 4. 9 Offset 5. VIEW AND EDIT 5. 1 Graphical View 5. 2 Create the Rectangular Point 5. 3 Edit the Data FREE STATIONING 6. 1 Stationing by more than 3 known points 6. 2 Stationing by two known points STAKE OUT 7. 1 Stake out 7. 2 Point to line CALCULATIONS 8. 1 COGO 8. 1. 1 Inverse 8. 1. 2 Point Coordinates 8. 1. 2. 1 Point Coordinates, Distance and H. [. . . ] PC:
SAVE
+ 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
LIST
ACCEPT
Press [ENT] to open the Y coordinate input screen and input.
Y 1. PC: POT1 + 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
CLEAR
77
Press [ENT] to open the Z coordinate input screen and input.
Z 1. PC: POT1 + 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
CLEAR
Press [ENT] to open the PC input screen and input.
PC 1. PC: POT1 + 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
BS
CLEAR
TO 123
B. End point coordinates input (Input the PN , Coordinates and PC of the End point. ) After PC input, EP screen is viewed.
EP 1. PC:
SAVE
+ 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
LIST
ACCEPT
78
Input the PN, X, Y, Z Coordinates and PC name of the End point.
Z 1. PC: POT1 + 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
CLEAR
Press [ENT] to view the RESULT OF INVERSE screen.
RESULT OF INVERSE
H. dst V. dst S. dst H. angle 0. 0000 m 0. 0000 m 0. 0000 m xxx° xx' xx"
ESC
ENT
C. Another End point Coordinates input Input the PN, X, Y, Z Coordinates and PC name of another End point, and the another inverse result can be performed.
INVERSE 1. PC:
SAVE
POT3 + 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
LIST
ACCEPT
RESULT OF INVERSE
H. dst V. dst S. dst H. angle 0. 0000 m 0. 0000 m 0. 0000 m xxx° xx' xx"
ESC
ENT
8. 1. 2 Points Coordinates
Bearing Distance
First Point
A point Coordinates is calculated from a known point Coordinates and the Distance and Horizontal angle of the second point. Input: Coordinates of a known point, Distance and Horizontal angle of the second point Output: Coordinates of the second point
80
From the PowerTopoLite screen, press [F2][CALC] to view the CALCULATION screen.
CALCULATION 1. REM
Select 1. COGO and press [ENT] to view the COGO screen.
COGO 1. CALCULATE
X Y Z +0. 000m +0. 000m +0. 000m
ESC
ENT
Press [ENT] to view the following screen.
RESULT OF COORD. PC:
+ XXXXXXXX. XXX m + XXXXXXXX. XXX m + XXXXXXXX. XXX m
ACCEPT
The PN, X, Y, Z and PC are viewed and can be edited. If all items are OK, press [F5][ACCEPT] to save them.
88
8. 1. 3 Circle Radius
P2
P3 Center P P1
Radius
The center point and radius of the circle drawn by three points are calculated by this function. Input: 3 points Output: Center point of the arc Radius of the arc From the PowerTopoLite screen, press [F2][CALC] to view the CALCULATION screen.
CALCULATION 1. REM
Select 1. COGO and press [ENT] to view the COGO screen.
COGO 1. CIRCLE RADIUS and press [ENT] to view CIRCLE RADIUS screen.
CIRCLE RADIUS 1. PC:
SAVE
+ 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
LIST
ACCEPT
Input PN (Point Name), X, Y, Z, and PC (Point Code) of P1 point or import from the memory of rectangular coordinate as P1 by [F2][LIST]. PC:
SAVE
+ 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
LIST
ACCEPT
90
Input P2 data like input of P1. PC:
SAVE
+ 00000000. 000 m + 00000000. 000 m + 00000000. 000 m
LIST
ACCEPT
If you finish the input of P3, press [F5][ACCEPT]. You can see the coordinates of center point of the arc and the radius of the arc.
RESULT OF CIRCLE RADIUS
X Y Z RADIUS +0. 000m +0. 000m +0. 000m +0. 000m
ESC
ENT
Press [F5][ENT] to save the coordinates of center point.
RESULT OF COORD. PC:
+ XXXXXXXX. XXX m + XXXXXXXX. XXX m + XXXXXXXX. XXX m
ACCEPT
The PN, X, Y, Z and PC are viewed and can be edited. [. . . ] When this option is selected, the menu screen will be shown after inputting necessary items.
RECTANGULAR COOR. REMOTE METHOD and press [ENT] to view the REMOTE METHOD selection window. Press [ENT] to select and press [F5][ACCEPT] to enter.
REMOTE METHOD 1. Cylinder face The Remote measurement is performed on the inner surface of the vertical cylinder as shown left.
Angle Cylinder
2. [. . . ]