User manual SMEG SRV576X.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SMEG SRV576X.1. We hope that this SMEG SRV576X.1 user guide will be useful to you.


SMEG SRV576X.1 : Download the complete user guide (634 Ko)

You may also download the following manuals related to this product:

   SMEG SRV576X.1 (701 ko)
   SMEG SRV576X.1 (664 ko)
   SMEG SRV576X.1 (662 ko)
   SMEG SRV576X.1 (746 ko)
   SMEG SRV576X.1 (641 ko)
   SMEG SRV576X.1 (676 ko)
   SMEG SRV576X.1 (655 ko)
   SMEG SRV576X.1 (746 ko)

Manual abstract: user guide SMEG SRV576X.1

Detailed instructions for use are in the User's Guide.

[. . . ] SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION "ZERO" (OFF) WHEN YOU FINISH USING THE HOB. 22 Introduction THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE HOB. [. . . ] For use with other types of gases, see Section " ADAPTATION TO DIFFERENT TYPES OF GAS". The gas intake fitting is ½" gas external threaded (ISO 2281). Connection with rigid copper pipe: the connection to the gas mains must not provoke stress of any kind on the hob. Connection may be made by using biconical adapter D with insertion of gasket C (supplied). Connection with flexible pipe: use only flexible pipes conforming to standard regulations in force, inserting gasket C (supplied) between fitting A and flexible pipe E. The flexible pipe has to be installed so that pipe length does not exceed 1. 5 meters of maximum extension. Make sure that the pipes do not touch any moving parts or become damaged. 27 Instructions for the installer 4. 1 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisions of standards regulations in force. Make sure that feed pressure conforms to the levels shown in the table in paragraph "5. 2 Regulation for LPG". 4. 2 Ventilation of rooms The hob may be installed only in rooms with permanent ventilation, as required by standards regulations in force. The room in which the hob is installed must have sufficient air flow to satisfy the requirements of normal gas combustion and of necessary air exchange in the room. The air intakes, protected by screens, must be appropriately sized (regulations in force) and placed so as not to be blocked in any way. The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking, and in the case of lengthy use a window should be opened or the speed of any ventilators should be increased. 4. 3 Discharge of combustion products Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration. An efficient aspiration system requires careful planning by a specialist capable of installing it, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity. 28 Instructions for the installer 5 ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, disconnect the appliance from the electrical socket. The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted. To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph. 5. 1 1. 6. Removing the hob Remove all the knobs, the grids, the burner caps and the flamecaps; Remove the screws and the nuts A that secure the burner supports; Remove plates B; Lift the hob from its seat; Replace the burner nozzles in accordance with the relevant gas table; Regulate the primary air as described in paragraph "5. 2 Regulation for LPG". 29 Instructions for the installer 5. 2 Regulation for LPG Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5. 4 Regulation of primary air" and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Burner Rated heating capacity LPG ­ G30/G31 28/37 mbar Nozzle By-pass diameter 1/100 mm 1/100 mm 48 30 (1) 62 30 (1) 76 37 (2) 85 43 67 43 (3) 87 55 (4) 42 30 (1) 87 55 (4) Reduced flowrate (W) Flowrate g/h G30 Flowrate g/h G31 Auxiliary Semirapid Rapid Rapid large Fish pan Ultra rapid Double Internal crown External 1. 05 1. 65 2. 55 3. 1 2 3. 3 0. 8 3. 3 380 380 650 750 750 1200 380 1200 76 120 185 225 145 240 58 240 75 118 182 222 143 236 57 236 (1)= 33 for valveless appliances. [. . . ] Your local authorised after-sales technician is able to supply professional products for appliance cleaning and care. Grids, caps, flame cap crowns and burners can be removed for ease of cleaning. Wash them in warm water using a non-abrasive detergent, taking care to remove all tough spots. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG SRV576X.1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG SRV576X.1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.