User manual X10 AD10E DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual X10 AD10E. We hope that this X10 AD10E user guide will be useful to you.


X10 AD10E DATASHEET: Download the complete user guide (80 Ko)

You may also download the following manuals related to this product:

   X10 AD10E DATASHEET (80 ko)

Manual abstract: user guide X10 AD10EDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] DIN Rail Switch 230VAC - 50 Hz - 16A LOAD RATING Key Features · Install at the breaker panel/fuse box for X10 control of branch lighting circuits or appliances rated up to 16A- ideal for airconditioning, heaters, etc. · Works with X10 controller and standard latched or momentary action wall switches - including "designer" wall switches. Product number : AD10E Benefits The X10 DIN rail switch is a remote controlled relay. [. . . ] Or alternatively, by individual unit control using "On" and "Off". When the relay is energized, the LED above the slide switch is illuminated. SLIDE SWITCH Typical applications This unit can replace any pulse contact relay that is commonly used for multi-switched hall and entry lighting. kitchen lighting, you may prefer to install the AD10E in a small sub-junction box. Technical data · Supply voltage: 230V +10% -15% 50 Hz · Supply current : 20 mA capacitive · Making capacity: - 2000 W ( incandescent lamp) - 3 A (motors) - 16 A (resistive loads) · EMC emission: according to EN 50081-1 · EMC immunity: according to EN 50082-1 · Electrical safety: according to EN 60950 and EN 60065 · Signal sensitivity: 15 mVpp min 50 mVpp max at 120 kHz · Input impedance: 180 Ohms (L - N) at 120 kHz · Connections: screw type terminals for phase, neutral, switched phase, control 1 and 2. · Ambient temperature: - 10° C to + 40° C (operation) - 20° C to + 70° C (storage) · Position 0: the connected load is switched off permanently and cannot be switched on by the wall switches or an X10 controller. · Position 1: the connected load is switched on permanently and cannot be switched off by the wall switches or an X10 controller. · Position auto: the connected load can be switched by the wall switches or an X10 controller. [. . . ] · Terminal 2 is designed for pulse contacts: each time phase is applied to the relay switches. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE X10 AD10E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual X10 AD10E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.