User manual ZANUSSI ZGS322TX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZANUSSI ZGS322TX. We hope that this ZANUSSI ZGS322TX user guide will be useful to you.


ZANUSSI ZGS322TX : Download the complete user guide (482 Ko)

Manual abstract: user guide ZANUSSI ZGS322TX

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction booklet Gas hob ZGS 322 GB Thank you for selecting our appliance We wish you lots of enjoyment with your new appliance and we hope that you will consider our brand again when purchasing household appliances. Please read this user manual carefully and keep it throughout the product life cycle as a reference document. The user manual should be passed on to any future owner of the appliance. 2 Contents Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description of the Hob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The hob is best cleaned whilst it is still warm, as spillage can be removed more easily than if it is left to cool. This appliance cannot be cleaned with steam or with a steam cleaning machine. Top The Hob Top Regularly wipe over the hob top using a soft cloth well wrung out in warm water to which a little wasing up liquid has been added. Avoid the use of the following: - household detergent and bleaches; - impregnated pads unsuitable for non-stick saucepans; - steel wool pads; - bath/sink stain removers. Should the hob top become heavily soiled, the following products are recommended: - For stainless steel hobs use a proprietary stainless steel cleaner. vinegar, salt, vinegar, lemon juice, etc. ) on the cooktop. Pan Supports The pan supports are dishwasher proof. If the marks are particularly difficult to remove, use common non-abrasive cleaners or specific products. Never use steel wool pads or acids. The Burners The burner caps and crowns can be removed for cleaning. Wash the burners caps and crowns using hot soapy water, and remove marks with a mild paste cleaner. A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth. 10 The Ignition electrode The electric ignition is obtained through a ceramic electrode which contains a metal electrode. Keep these components very clean, to avoid difficult lighting, and check that the burner crown holes are not obstructed. 11 Something Not Working? If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre. Tap By-pass 1/100 mm 28 42 Auxiliary Rapid Aeration adjustment none 14 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. Provision Ventilation Pr ovision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 100 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I. S. 813 Current Editions Table Four. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Ensure that there is a minimum distance of 55 mm between the rear cut out edge and the wall. [. . . ] Repeat this procedure for all burners. Minimum adjustment screw Pressur Testing essure Pr essur e Testing The pressure testing must be carried out on the burners. Proceed as follows: 1) Remove the pan supports and the burner caps and crowns. The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar. 4) Turn off the burner supplies. 25 Conversion from Natural Gas to LPG IMPORT IMPOR TANT The replacement/conversion from natural gas to LPG should only be undertaken by a competent person. It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGS322TX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGS322TX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.