User manual ZIBRO R616C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO R616C. We hope that this ZIBRO R616C user guide will be useful to you.


ZIBRO R616C : Download the complete user guide (1931 Ko)

Manual abstract: user guide ZIBRO R616C

Detailed instructions for use are in the User's Guide.

[. . . ] Your heater comes with a 48-month manufacturer's warranty on all defects in material or workmanship. We wish you much warmth and comfort with your Zibro. Yours sincerely, PVG International b. v. Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST. 2 IN CASE OF ANY DOUBT, CONTACT YOUR ZIBRO DEALER. 3 BEFORE YOU START READING, FOLD OUT THE LAST PAGE. 4 50 GENERAL DIRECTIONS FOR USE Below you will find the main steps to be taken for using your Zibro. For more details, please refer to the MANUAL (pages 53 ff. ). MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank 1 2 3 4 5 Remove all packaging materials (Fig. D). Operation panel Handle Removable tank Air filter Vent filter Thermostat Plug + cord Information display key Childproof lock Adjustment keys (time and temperature) TIMER SAVE key Indicator lights Insert the plug into the wall-socket. Ignite the heater using the key (refer to Section D). If required, change the temperature using the adjustment keys (refer to Section E). 6 Switch off the heater by pressing the key . The first time you ignite your heater it will smell like 'new' for a short time. [. . . ] The latter can be changed with the adjustment keys (refer to Section E). Prior to igniting the heater, always check for sufficient fuel in the removable tank. SETTING THE REQUIRED TEMPERATURE The temperature setting can only be adjusted, when the heater is burning. First press either of the two keys to switch on the function (the C mark and 4-digit will start blinking). Next, adjust the temperature using the key (Mmin. ) to set the temperature to a higher setting and the key (Nhour) to lower the temperature. After approximately 10 seconds the C mark and 4-digit will stop blinking and the setting will be locked (Fig. The available temperature settings range from 6C minimum to 28C maximum. When the heater has been unplugged for more than 10 minutes (or after a power failure), the temperature will reset to the factory setting of 20C. F USING THE TIMER The timer allows you to switch on the heater automatically at a preset time. In order to switch on the timer, the correct time must have been set (refer to Section C) and the heater should be off. Follow the procedure below: 4 54 1 Press the button and then the TIMER key immediately after that. 2 Use the adjustment keys to set the time at which the heater must ignite. Use the key (Nhour) to set the hours and the key (Mmin. ) to set the minutes (interval of 5 minutes). In the display the number 90/60 will appear, which will decline to 10. At the arrival of 10, you will hear an alarm signal every two minutes, warning you to refill the removable tank. The fuel indicator will blink, while four lines (--:--) are blinking in the information once more. You can stop this by pressing the button Once the heater has used up all its fuel and extinguished, it will take some time, after the refill, before the heater is completely ready for use again. K: When the FUEL indicator has appeard, the information display will show the number of minutes of fuel left in the tank. THE 'VENT' INDICATOR When there is insufficient ventilation in the room, an intermittent buzzer will be heard (approximately once each 30 seconds) and the VENT indicator will be blinking. When this signal is given, ensure that the ventilation of the room is improved (e. g. by opening a door or window a little more), to avoid that the heater shuts off. When the ventilation of the room is improved, the VENT indicator and buzzer will be deactivated. When there is still insufficient ventilation, the heater shuts off automatically. When this occurs, e -1 1 is displayed and the indicator is blinking and VENT indicator ( ) is lit. by opening a door or window a little more), the heater can be ignited by again. pushing L: A blinking indicator light is a sign that you need extra ventilation. MAINTENANCE Switch off the heater and let it cool down, before you start any maintenance work. [. . . ] Direct measurement of the CO2 level (NDIR CO2-sensor E-Guard * At maximum setting ** Specified values are indicative 4 58 Q WARRANTY PROVISIONS Your heater comes with a 48-month warranty starting on the date of purchase. Within this period all defects in material or workmanship will be repaired without any charge. The following provisions shall apply regarding this warranty: 1 We expressly dismiss all other claims for damages, including consequential damages. 2 Any repairs or replacements of components within the term of warranty will not result in an extension of the term of warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO R616C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO R616C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.