User manual ZIBRO SRE 25 E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO SRE 25 E. We hope that this ZIBRO SRE 25 E user guide will be useful to you.


ZIBRO SRE 25 E : Download the complete user guide (908 Ko)

You may also download the following manuals related to this product:

   ZIBRO SRE 25 E (886 ko)
   ZIBRO SRE 25 E (884 ko)
   ZIBRO SRE 25 E (883 ko)

Manual abstract: user guide ZIBRO SRE 25 E

Detailed instructions for use are in the User's Guide.

[. . . ] When there is insufficient ventilation in the room or when the heater is being used in a room which is too small, the heater will shut off automatically. For comfortable and safe heating ensure that there is sufficient ventilation. Note: To avoid unexpected shut off, we recommend to put a door or window ajar when the heater is operating. For each model the minimum size of space is specified in which you can use the heater safely, without additional ventilation (refer to Section O). [. . . ] The available temperature settings range from 6C minimum to 28C maximum. When the heater has been unplugged (or after a power failure), the temperature will reset to the factory setting of 20C. F USING THE TIMER The timer allows you to switch on the heater automatically at a preset time. In order to switch on the timer, the correct time must have been set (refer to Section C) and the heater should be off. Follow the procedure below: 1 Press the button and then the TIMER key immediately after that. The TIMER lamp and the 4-digit will start blinking. to set the time at which the heater must ignite. 2 Use the adjustment keys Use the key on the left (Nhour) to set the hours and the key on the right (Mmin. ) to set the minutes (interval of 5 minutes). 3 After approximately 10 seconds the 4-digit will show CLOCK again and the TIMER lamp G: The TIMER indicator light indicates that the timer function has been switched on. will light up, indicating that the timer function has been activated (Fig. G). 4 The timer will ensure that the room will have been heated to approximately the required temperature at the set time. G When you want to switch off the heater and ignite it again with the timer, all you have to do is press the TIMER key (refer to Section G). Press the button once to clear the timer setting. SWITCHING OFF THE HEATER There are two ways to switch off the heater. 1 Press the button . Within approximately one minute the flame will have extinguished. 2 Press the TIMER key , when you want to switch off the heater and ignite it again with the timer the next time. This not only switches off the heater, but it also activates the timer function. You can change the required time with the adjustment keys (refer to Section F). 4 67 H THE INFORMATION DISPLAY The information display not only serves as an indicator of the (set) time and temperature (sections C, E, and F), it also indicates any malfunctioning of the heater. The code on the information display tells you what is the matter: CODE INFORMATION Temperature within the heater too high. The heater has been in operation continuously for a period of 48 hours and has turned itself off automatically. Contact your dealer. In case of any malfunctioning the information display will tell you what is the matter. efefeeee- 0 0 1 1 2 5 6 7 e- 8 e- 9 -- : --- : -- + e-11+ + Out of fuel. Too little ventilation. Always contact your dealer for any malfunctioning not listed above. AUTOMATIC DEACTIVATION This heater is fitted with a safety system that ensures that it switches off automatically after 48 hours continuous operation. If desired, you can switch the heater on again by pressing button (see section D). AUTOMATIC CLEANING MODE When the heater has been burning continuously for two hours at its highest setting, the burner will automatically start an autoclean procedure. The display will show the autocleaningcode cl 05 running back to cl 01. The procedure takes 5 minutes, during which the heater will burn at its lowest setting, while the burner autocleans. The count-down of the remaining heating time can be seen in the information display (Fig. Every two minutes an alarm signal is sounded, warning you to refill the removable tank. The FUEL indicator will blink, while four lines are blinking in the information display. Once the heater has used up all its fuel and is extinguished it will take some time, after the refill, before the heater is completely ready for use again. L THE 'VENT' INDICATOR When there is insufficient ventilation in the room, an intermittent buzzer will be heard (approximately once each 30 seconds) and the VENT indicator will be lit. When this signal is given, ensure that the ventilation of the room is improved (e. g. [. . . ] The Zibro SRE 25 E is supplied with an exchangeable stainless steel front panel. www. zibro. com 1 2 3 4 5 6 4 72 7 8 9 10 11 12 4 73 DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL b. v. i STERREICH PVG Austria VertriebsgmbH Salaberg 49 3350 HAAG tel: +43 7434 44867 fax: +43 7434 44868 email: pvgaustria@zibro. com e BELGI PVG Belgium NV/SA Industrielaan 55 2900 SCHOTEN tel: +32 3 326 39 39 fax: +32 3 326 26 39 email: pvgbelgium@zibro. com q SCHWEIZ PVG Schweiz AG Salinenstrasse 63 4133 PRATTELN tel: +41 61 337 26 51 fax: +41 61 337 26 78 email: pvgint@zibro. com 2 DEUTSCHLAND PVG Deutschland GmbH Siemensstrasse 31 47533 KLEVE tel: 0800 - 9427646 fax: +31 (0)412 648 385 email: pvgdeutschland@zibro. com 6 DANMARK Appliance A/S Blovstroed Teglvaerksvej 3 DK-3450 ALLEROED tel: +45 70 205 701 fax: +45 70 208 701 email: appliance@appliance-group. com 5 ESPAA PVG Espaa S. A. San Jos de Valderas II Comunidad "La Alameda" C/ Aurora Boreal, 19 28918 LEGANS (Madrid) tel: +34 91 611 31 13 fax: +34 91 612 73 04 email: pvgspain@zibro. com 3 FRANCE PVG France SARL 4, Rue Jean Siblius B. P. 185 76410 SOTTEVILLE SOUS LE VAL +33 2 32 96 07 47 tel: fax: +33 0 820 34 64 84 email: pvgfrance@zibro. com F I N SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO +358 9 4390 030 tel: fax: +358 9 4390 0320 email: appliance@appliance-group. com 4 UNITED KINGDOM Scott Brothers Ltd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO SRE 25 E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO SRE 25 E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.